DOUBLE-CONTRAST BARIUM ENEMA STUDIES - EFFECT OF MULTIPLE READING ON PERCEPTION ERROR

被引:61
作者
MARKUS, JB [1 ]
SOMERS, S [1 ]
OMALLEY, BP [1 ]
STEVENSON, GW [1 ]
机构
[1] HENDERSON GEN HOSP,DEPT RADIOL,HAMILTON L8V 1C3,ONTARIO,CANADA
关键词
D O I
10.1148/radiology.175.1.2315474
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The images from 60 double-contrast barium enema (DCBE) examinations of patients who had also undergone colonoscopy were reviewed independently by three radiologists. The average radiologist detected 70.2% of the 46 radiologically visible lesions. The reports of the individual observers were combined to generate double and triple reading reports. The corresponding average double and triple reading combinations resulted in detection of 83.3% and 89.0%, respectively, of the visible lesions. These increases in sensitivity over those of the readings of the single observers were clinically and statistically significant. They were, however, accompanied by some decreases in specificity. The results confirm the concept that false-negative perception error is a major problem in the interpretation of DCBE examinations and indicate that multiple reading is an effecctive way to reduce this error.
引用
收藏
页码:155 / 156
页数:2
相关论文
共 18 条
  • [1] BOLIN S, 1988, CANCER-AM CANCER SOC, V61, P1999, DOI 10.1002/1097-0142(19880515)61:10<1999::AID-CNCR2820611012>3.0.CO
  • [2] 2-W
  • [3] EISENBERG RL, 1983, GASTROINTESTINAL RAD, P686
  • [4] FLEISS JL, 1981, STAT METHODS RATES P, pCH8
  • [5] DOUBLE CONTRAST EXAMINATION IN CARCINOMA OF THE COLON AND RECTUM - A PROSPECTIVE CLINICAL-SERIES
    FORK, FT
    LINDSTROM, C
    EKELUND, G
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1983, 24 (03): : 177 - 188
  • [6] RELIABILITY OF ROUTINE DOUBLE-CONTRAST EXAMINATION (DCE) OF THE LARGE BOWEL IN POLYP DETECTION - A PROSPECTIVE CLINICAL-STUDY
    FORK, FT
    LINDSTROM, C
    EKELUND, GR
    [J]. GASTROINTESTINAL RADIOLOGY, 1983, 8 (02): : 163 - 172
  • [7] IMPROVING PERFORMANCE BY MULTIPLE INTERPRETATIONS OF CHEST RADIOGRAPHS - EFFECTIVENESS AND COST
    HESSEL, SJ
    HERMAN, PG
    SWENSSON, RG
    [J]. RADIOLOGY, 1978, 127 (03) : 589 - 594
  • [8] HUNT RH, 1981, COLONOSCOPY TECHNIQU, P237
  • [9] KELVIN FM, 1987, RADIOLOGY, V164, P1
  • [10] COLORECTAL-CARCINOMA MISSED ON DOUBLE CONTRAST BARIUM ENEMA STUDY - A PROBLEM IN PERCEPTION
    KELVIN, FM
    GARDINER, R
    VAS, W
    STEVENSON, GW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) : 307 - 313