A MICROELECTROCHEMICAL ENZYME TRANSISTOR RESPONSIVE TO GLUCOSE

被引:101
作者
BARTLETT, PN
BIRKIN, PR
机构
[1] Department of Chemistry, University of Southampton, Southampton
关键词
D O I
10.1021/ac00081a031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microelectrochemical enzyme transistors, or enzyme switches, were prepared by connecting two carbon band electrodes (similar to 10 mu m wide, 4.5 mm long separated by a 20-mu m gap) with an anodically grown film of poly(aniline). Glucose oxidase (GOx, EC 1.1.3.4) was immobilized onto the poly(aniline) film in an insulating poly(1,2-diaminobenzene) polymer grown electrochemically oh top of the poly(aniline) film to complete the device. In the completed device the conductivity of the poly(aniline) film changes from insulating (>+0.3 V vs SCE at pH 5) to conducting (between -0.05 and +0.3 V vs SCE at pH 5) on-addition of glucose in the presence of TTF+ (tetrathiafulvalenium). The change in conductivity is brought about by reduction of the poly(aniline) by the enzyme mediated by TTF+ present in the homogeneous solution. This was confirmed by measuring the potential of the poly(aniline) film during switching of the conductivity in the presence of glucose. The devices can be reused by reoxidizing the poly(aniline) electrochemically at +0.5 V vs SCE. The effect of varying the poly(aniline) growth charge on the switching rate was investigated along with the conditions for the immobilization of the enzyme. The switching time has been optimized so that the device takes 10 s to switch from fully insulating to fully conducting. The sensitivity to glucose and other sugars is shown along with studies of the effects of interferent species.
引用
收藏
页码:1552 / 1559
页数:8
相关论文
共 24 条
[1]   IMPROVED COLOR REAGENT FOR DETERMINATION OF BLOOD-GLUCOSE BY OXIDASE SYSTEM [J].
BARHAM, D ;
TRINDER, P .
ANALYST, 1972, 97 (1151) :142-&
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[3]   ENZYME SWITCH RESPONSIVE TO GLUCOSE [J].
BARTLETT, PN ;
BIRKIN, PR .
ANALYTICAL CHEMISTRY, 1993, 65 (08) :1118-1119
[4]   THE APPLICATION OF CONDUCTING POLYMERS IN BIOSENSORS [J].
BARTLETT, PN ;
BIRKIN, PR .
SYNTHETIC METALS, 1993, 61 (1-2) :15-21
[5]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[6]   DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .1. ELECTRON-TRANSFER FROM GLUCOSE-OXIDASE TO METAL-ELECTRODES VIA ELECTRON RELAYS, BOUND COVALENTLY TO THE ENZYME [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (06) :1285-1289
[7]  
Dixon M, 1979, ENZYMES, P243
[8]   RESPONSE OF AN ENZYME-MODIFIED PH-SENSITIVE ION-SELECTIVE DEVICE - EXPERIMENTAL-STUDY OF A GLUCOSE OXIDASE MODIFIED ION-SENSITIVE FIELD-EFFECT TRANSISTOR IN BUFFERED AND UNBUFFERED AQUEOUS-SOLUTION [J].
EDDOWES, MJ ;
PEDLEY, DG ;
WEBB, BC .
SENSORS AND ACTUATORS, 1985, 7 (04) :233-244
[9]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[10]   BIOSENSOR BASED ON CONDUCTING POLYMERS [J].
HOA, DT ;
KUMAR, TNS ;
PUNEKAR, NS ;
SRINIVASA, RS ;
LAL, R ;
CONTRACTOR, AQ .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2645-2646