COMPARATIVE SPERM CHROMATIN STRUCTURE ASSAY MEASUREMENTS ON EPIILLUMINATION AND ORTHOGONAL AXES FLOW CYTOMETERS

被引:15
作者
EVENSON, D
JOST, L
GANDOUR, D
RHODES, L
STANTON, B
CLAUSEN, OP
DEANGELIS, P
COICO, R
DALEY, A
BECKER, K
YOPP, T
机构
[1] BECTON DICKINSON IMMUNOCYTOMETRY SYST,SAN JOSE,CA 95131
[2] COULTER CORP,HIALEAH,FL
[3] NATL HOSP NORWAY,INST PATHOL,OSLO,NORWAY
[4] CUNY,SCH MED,DEPT MICROBIOL & IMMUNOL,NEW YORK,NY 10031
[5] PHOENIX FLOW SYST INC,SAN DIEGO,CA
[6] PALO VERDE SOFTWARE INC,TUCSON,AZ
来源
CYTOMETRY | 1995年 / 19卷 / 04期
关键词
EPIILLUMINATION; ORTHOGONAL; FLOW CYTOMETER; SCSA; SPERM CHROMATIN STRUCTURE;
D O I
10.1002/cyto.990190403
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The sperm chromatin structure assay (SCSA) measures the susceptibility of sperm nuclear DNA to acid-induced denaturation in situ, and was developed on two Ortho flow cytometers, an FC200 [Becton Dickinson Immunocytometry Systems (BDIS), Westwood, MA] and a Cytofluorograf 30 (BDIS), both having orthogonal axes of fluorochrome excitation, emission, and sample how. Sperm cells are first treated with a pH 1.4 buffer to denature DNA in situ and then stained with the metachromatic dye acridine orange (AO). The metachromatic fluorescence measured reflects relative amounts of denatured (red fluorescence) and native (green fluorescence) DNA present per cell. The extent of DNA denaturation is quantified by the calculated parameter alpha t [alpha(t) = red/(red + green) fluorescence]. Alpha t variables important for correlations with fertility and toxicant-induced chromatin damage include mean (X alpha(t)) standard deviation (SD alpha(t)), and cells outside the main population (COMP alpha(t)). Mean green fluorescence intensity is an important measure for DNA content and/or degree of sperm chromatin condensation. This study showed that the SCSA can be successfully run on two epiillumination-type instruments, an Ortho ICP22A (BDIS, San Jose, CA) and Skatron Argus(TM) (Tranby, Norway), and two additional orthogonal axes instruments, a Becton Dickinson FACScan(TM) (BDIS) and a Coulter Elite(TM) (Coulter Corporation, Hialeah, FL). Epiillumination instruments produced a different fluorescence distribution than orthogonal instruments, but the resulting alpha(t), values showed strong conformity and interpretation of results was the same. SCSA values obtained on the Coulter Elite(TM) were most similar to the Cytofluorograf 30; the FACScan(TM) green fluorescence distribution was narrower and allowed resolution of cell doublets. Neither orthogonal instrument has the ability to directly calculate cw, values. Listmode data from these instruments were transferred to an off-line personal computer (PC) for calculation of alpha(t) values using LIST-VLEW(TM) software (Phoenix Flow Systems, Inc., San Diego, CA). (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:295 / 303
页数:9
相关论文
共 28 条
[1]   HETEROGENEITY OF SPERM NUCLEAR CHROMATIN STRUCTURE AND ITS RELATIONSHIP TO BULL FERTILITY [J].
BALLACHEY, BE ;
HOHENBOKEN, WD ;
EVENSON, DP .
BIOLOGY OF REPRODUCTION, 1987, 36 (04) :915-925
[2]  
BALLACHEY BE, 1988, J ANDROL, V9, P109
[3]  
DARZYNKIEWICZ Z, 1975, EXP CELL RES, V90, P411
[4]   LYMPHOCYTE STIMULATION - RAPID MULTIPARAMETER ANALYSIS [J].
DARZYNKIEWICZ, Z ;
TRAGANOS, F ;
SHARPLESS, T ;
MELAMED, MR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1976, 73 (08) :2881-2884
[5]  
Darzynkiewicz Z., 1990, FLOW CYTOMETRY SORTI, V2nd, P291
[6]   CHANGES IN ACCESSIBILITY OF DNA TO VARIOUS FLUOROCHROMES DURING SPERMATOGENESIS [J].
EVENSON, D ;
DARZYNKIEWICZ, Z ;
JOST, L ;
JANCA, F ;
BALLACHEY, B .
CYTOMETRY, 1986, 7 (01) :45-53
[7]  
EVENSON D, 1994, METHOD CELL BIOL, V42, P159
[8]  
Evenson D P, 1990, Methods Cell Biol, V33, P401
[9]  
Evenson D.P., 1989, FLOW CYTOMETRY ADV R, VI, P217
[10]   LONG-TERM EFFECTS OF TRIETHYLENEMELAMINE EXPOSURE ON MOUSE TESTIS CELLS AND SPERM CHROMATIN STRUCTURE ASSAYED BY FLOW-CYTOMETRY [J].
EVENSON, DP ;
BAER, RK ;
JOST, LK .
ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 1989, 14 (02) :79-89