DETERMINATION OF THE ENANTIOMERS OF FENOLDOPAM IN HUMAN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AFTER CHIRAL DERIVATIZATION

被引:7
|
作者
BOPPANA, VK
GESCHWINDT, L
CYRONAK, MJ
RHODES, G
机构
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 592卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)85102-Y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fenoldopam, a selective agonist at peripheral dopaminergic (DA-1) receptors, is administered as a racemic mixture and, consequently, an indirect stereospecific high-performance liquid chromatographic assay was developed to study the disposition of the individual enantiomers in human subjects. Fenoldopam enantiomers were extracted from alkalinized plasma into ethyl acetate prior to precolumn derivatization with the chiral reagent 2,3,4,6-tetra-O-acetyl-beta-D-glucopyranosyl isothiocyanate (GITC). The resulting diastereomers were separated on a reversed-phase butylsilica column and determined using triple-electrode coulometric detection. The limits of determination and detection for the S- and R-enantiomers of fenoldopam were 0.5 and 0.25 ng/ml, respectively. A linear response was observed for (S)- and (R)-fenoldopam concentrations ranging from 0.5 to 50 ng/ml in plasma. The intra-day relative standard deviations (R.S.D.s) for the plasma assay at nominal concentrations of 0.5, 5 and 50 ng/ml were 17.4, 5.2 and 6.9%, respectively, for (S)-fenoldopam and 9.9, 6.2 and 7.4%, respectively, for (R)-fenoldopam. The inter-day R.S.D.s of the method at these concentrations were 9.3, 7.7 and 7.4%, respectively, for (S)-fenoldopam and 9.5, 1.9 and 7.3%, respectively, for (R)-fenoldopam. The mean accuracy of the method at concentrations of 0.5, 5 and 50 ng/ml in plasma was found to be 106.4, 111.8 and 108.9%, respectively, for (S)-fenoldopam and 116.2, 104.2 and 111.2%, respectively, for (R)-fenoldopam. The assay developed was sufficiently sensitive, accurate and precise to support pharmacokinetic studies in human subjects.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 50 条
  • [1] SIMULTANEOUS DETERMINATION OF PROPRANOLOL AND 4-HYDROXYPROPRANOLOL ENANTIOMERS AFTER CHIRAL DERIVATIZATION USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SCHAEFER, HG
    SPAHN, H
    LOPEZ, LM
    DERENDORF, H
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 527 (02): : 351 - 359
  • [2] DETERMINATION OF PLASMA OXALATE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    JEREZ, E
    REVISTA ESPANOLA DE FISIOLOGIA, 1986, 42 (04): : 441 - 447
  • [3] THE DETERMINATION OF BROMAZEPAM IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LESOLLEU, H
    DEMOTESMAINARD, F
    VINCON, G
    BANNWARTH, B
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (08) : 771 - 775
  • [4] DETERMINATION OF VIGABATRIN IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TSANACLIS, LM
    WICKS, J
    WILLIAMS, J
    RICHENS, A
    THERAPEUTIC DRUG MONITORING, 1991, 13 (03) : 251 - 253
  • [5] DETERMINATION OF ANTIPYRINE IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CAMPBELL, TM
    MURDAUGH, EW
    KILLENBERG, PG
    JOURNAL OF CHROMATOGRAPHY, 1979, 163 (02): : 236 - 238
  • [6] DETERMINATION OF KETANSERIN IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DAVIES, CL
    JOURNAL OF CHROMATOGRAPHY, 1983, 275 (01): : 232 - 233
  • [7] DETERMINATION OF QUERCETIN IN HUMAN PLASMA USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LIU, B
    ANDERSON, D
    FERRY, DR
    SEYMOUR, LW
    DETAKATS, PG
    KERR, DJ
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 666 (01): : 149 - 155
  • [8] DETERMINATION OF NADOXOLOL IN HUMAN PLASMA USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MISZTAL, G
    PRZYBOROWSKI, L
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 660 (02): : 409 - 411
  • [9] DETERMINATION OF PIPOTHIAZINE IN HUMAN-PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OGDEN, DA
    MCKECHNIE, AA
    BOLTON, DA
    RANKIN, RB
    DOBBINS, SE
    CLEMENTS, JA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (11) : 1273 - 1280
  • [10] DETERMINATION OF CORTISOL IN HUMAN-PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SCOTT, NR
    DIXON, PF
    JOURNAL OF CHROMATOGRAPHY, 1979, 164 (01): : 29 - 34