TOWER SURGE IMPEDANCE

被引:118
作者
SARGENT, MA
DARVENIZA, M
机构
[1] University of Queensland, Department of Electrical Engineering, St. Lucia, Brisbane
来源
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS | 1969年 / PA88卷 / 05期
关键词
D O I
10.1109/TPAS.1969.292357
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Experimental and theoretical methods for determining the surge impedance of towers are presented. It is demonstrated that the values so obtained adequately describe the response of the tower when a transmission line is struck by lightning. A right cone representation for conventional double-circuit steel towers is proposed, and a theoretical analysis using field theory yields the surge impedance as Z= 60 In (S) where S is the sine of the half-angle of the cone. Copyright © 1969 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:680 / +
页数:1
相关论文
共 10 条
  • [1] ANDERSON JG, 1958, AIEE T, V77, P1644
  • [2] [Anonymous], 1960, AIEE T POWER APP SYS
  • [3] BREUER GD, 1957, AIEE T 3, V76, P1392
  • [4] CASWELL RW, 1957, AIEE T, V76, P1480
  • [5] GRANT IS, 1967, ELECTRICAL ENGINEERI, VEE3, P131
  • [6] Jordan C.A., 1934, GEN ELECTR REV, V34, P180
  • [7] Jordan C. A., 1934, GEN ELECTR REV, V37, P180
  • [8] JORDAN CA, 1934, GEN ELECTR REV, V37, P243
  • [9] Kawai M., 1964, IEEE T POWER APPL SY, V83, P30, DOI DOI 10.1109/TPAS.1964.4765920
  • [10] CALCULATION OF DOUBLE CIRCUIT OUTAGE RATE OF TRANSMISSION LINES
    SARGENT, MA
    DARVENIZA, M
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1967, PA86 (06): : 665 - +