DETERMINATION OF SCANDIUM IN HIGH-PURITY TITANIUM USING INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY AND GLOW-DISCHARGE MASS-SPECTROMETRY AS PART OF ITS CERTIFICATION AS A REFERENCE MATERIAL

被引:8
作者
HELD, A
TAYLOR, P
INGELBRECHT, C
DEBIEVRE, P
BROEKAERT, JAC
VANSTRAATEN, M
GIJBELS, R
机构
[1] UNIV DORTMUND,W-4600 DORTMUND,GERMANY
[2] UNIV INSTELLING ANTWERP,ANTWERP,BELGIUM
关键词
NEUTRON REFERENCE MATERIALS; SCANDIUM DETERMINATION; INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; GLOW DISCHARGE MASS SPECTROMETRY; TITANIUM METAL;
D O I
10.1039/ja9951000849
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Scandium was determined in high-purity titanium by inductively coupled plasma mass spectrometry (ICP-MS) and glow discharge mass spectrometry (GDMS), The analysis was carried out as part of the certification campaign for certifying Sc in a titanium neutron dosimetry reference material (NRM 531) from the Institute of Reference Materials and Measurements (IRMM). The scandium concentration in the titanium was found to be less than 2.5 ng g(-1). This is based on the analysis of four NRM 531 titanium samples. This value was established using ICP-R?IS preceded by ion exchange for the matrix separation, The mean recovery for this separation was 92 +/- 12%, A comparative measurement using GDMS confirmed the results obtained by ICP-MS. The relative sensitivity factor of scandium in titanium, RSF(Sc/Ti), for GDMS was determined by using four doped titanium samples prepared at IRMM. The data for the doped titanium samples were cross checked using ICP-MS. NRM 531 titanium was analysed four times with GDMS and scandium levels were found to be below the detection limit of 25 ng g(-1). This relatively high detection limit for GDMS was due to an interfering polyatomic species on the same nominal mass as scandium ((TiAr2+)-Ti-50-Ar-40). The features of the two methods used in this work were compared.
引用
收藏
页码:849 / 852
页数:4
相关论文
共 9 条
[1]   CONCENTRATION, SEPARATION AND DETERMINATION OF SCANDIUM, ZIRCONIUM, HAFNIUM AND THORIUM WITH A SILICA-BASED SULFONIC-ACID CATION-EXCHANGER [J].
ALIMARIN, IP ;
FADEEVA, VI ;
KUDRYAVTSEV, GV ;
LOSKUTOVA, IM ;
TIKHOMIROVA, TI .
TALANTA, 1987, 34 (01) :103-110
[2]   ALLOY PREPARATION BY LEVITATION MELTING [J].
INGELBRECHT, C ;
PEETERMANS, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 334 (01) :116-121
[3]   SEPARATION OF RARE EARTHS FROM BERYLLIUM, MAGNESIUM, ZIRCONIUM, TITANIUM, URANIUM, AND STAINLESS STEEL [J].
LERNER, MW ;
PINTO, LJ .
ANALYTICAL CHEMISTRY, 1959, 31 (04) :549-551
[4]   ION EXCHANGE PROCEDURES .1. CATION EXCHANGE IN CONCENTRATED HCL + HCLO4 SOLUTIONS [J].
NELSON, F ;
MURASE, T ;
KRAUS, KA .
JOURNAL OF CHROMATOGRAPHY, 1964, 13 (02) :503-&
[5]  
ROMANTSEVA TI, 1981, ZH ANAL KHIMII, V36, P1529
[6]   CATION-EXCHANGE IN TARTARIC ACID NITRIC-ACID AND IN TARTARIC ACID AMMONIUM-TARTRATE SOLUTION [J].
STRELOW, FWE ;
VANDERWALT, TN .
ANALYTICAL CHEMISTRY, 1982, 54 (03) :457-462
[7]   A EUROPEAN-COMMUNITY SOURCE OF REFERENCE MATERIALS FOR NEUTRON METROLOGY REQUIREMENTS [J].
VANAUDENHOVE, J ;
PAUWELS, J ;
FUDGE, AJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 236 (03) :600-603
[8]   ANALYSIS OF PLATINUM POWDER BY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
VANSTRAATEN, M ;
SWENTERS, K ;
GIJBELS, R ;
VERLINDEN, J ;
ADRIAENSSENS, E .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) :1389-1397
[9]  
ASTM E52687 AM SOC T