ENDLESS-LOOP TACHYCARDIAS - DESCRIPTION AND 1ST CLINICAL-RESULTS OF A NEW FULLY-AUTOMATIC PROTECTION ALGORITHM

被引:14
作者
NITZSCHE, R
GUEUNOUN, M
LAMAISON, D
LASCAULT, G
PIOGER, G
RICHARD, M
MALHERBE, O
LIMOUSIN, M
机构
[1] CTR HOSP REG & UNIV,HOSP NORD,MARSEILLE,FRANCE
[2] CTR HOSP REG & UNIV,CLERMONT FERRAND,FRANCE
[3] HOP JEAN ROSTAND,IVRY,FRANCE
[4] CLIN ALLERAY,PARIS,FRANCE
[5] CTR HOSP ST MAIO,ST MALO,FRANCE
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 12期
关键词
DDD PACING; ENDLESS-LOOP TACHYCARDIA; RETROGRADE CONDUCTION;
D O I
10.1111/j.1540-8159.1990.tb06877.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Endless-loop tachycardia (ELT) is one of the most common pacemaker mediated tachycardia. An innovative ELT protection algorithm has proven to be clinically effective. A new improved version that will eliminate the need to program any parameter is now under clinical evaluation. Nine patients entered the study: six men and three women, aged 52 +/- 22 years. This automatic algorithm needs only 10 cycles to detect and confirm an ELT. Three hundred thirty-three ELTs lasting more than 9 cycles have been induced and analyzed. The total results are the following: mean duration: 6.7 sec +/- 3.1; mean ELT rate: 137 +/- 21.9 bpm, mean programmed upper rate limit (URL): 142.5 +/- 26.5 bpm (Only 70% of ELTs presented rates equal to programmed URL). (1) ELTs reduced by postventricular atrial refractory period (PVARP) extension on one cycle: 291 ELTs (87%). ELT rate: 128.5 +/- 18.2 bpm. (2) Retrograde block: algorithm operation may induce a retrograde block due to a short atrioventricular delay (AVD) applied during the confirmation phase to discriminate an ELT from a stable sinus rhythm. Thirty-two ELTs (10%) have been reduced and detected on a retrograde block occurrence. (3) Algorithm failure due to an unstable ventriculoatrial conduction time (VACT) even at fixed rate or to a retrograde Wenckebach behavior on AVD reduction during the confirmation phase. A total of 10 algorithms failed to detect or confirm an ELT have been recorded (3%). Mean duration: 8.2 +/- 4.2 sec, mean ELT rate: 148.9 +/- 14.3 bpm. This new fully automatic algorithm has reduced 97% of ELTs, including high rate episodes (100-175 bpm). It allows 1:1 tracking adapted to the needs of the patient, by programming a short PVARP and a physiological AVD.
引用
收藏
页码:1711 / 1718
页数:8
相关论文
共 15 条
[1]  
AKHTAR M, 1985, CLIN PROG PACING ELE, V3, P90
[2]   ARTIFICIAL CIRCUS MOVEMENT TACHYCARDIAS - INCIDENCE, MECHANISMS, AND PREVENTION [J].
BERTHOLET, M ;
MATERNE, P ;
DUBOIS, C ;
MARCELLE, P ;
BECKERS, J ;
DEMOULIN, JC ;
FOURNY, J ;
KULBERTUS, HE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03) :415-423
[3]  
CALFEE RV, 1988, NEW PERSPECTIVES CAR, P357
[4]  
DENDULK K, 1986, CLIN PROG ELECTROPHY, V4, pA69
[5]  
FRANKLIN JO, 1989, 4TH P EUR S CARD PAC, P81
[6]   DUAL CHAMBER PACEMAKERS - UPPER RATE BEHAVIOR [J].
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (02) :197-214
[7]  
GIRODO S, 1988, NEW PERSPECTIVES CAR, P405
[8]  
GIRODO S, 1989, 4TH P EUR S CARD PAC, P83
[9]   PACEMAKER-MEDIATED TACHYCARDIAS - AN UNRESOLVED PROBLEM [J].
HARTHORNE, JW ;
EISENHAUER, AC ;
STEINHAUS, DM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (06) :1140-1147
[10]  
KLEMENTOWICZ P, 1986, CLIN PROG ELECTROPHY, V4, pA68