IMMOBILIZED METAL-ION AFFINITY-CHROMATOGRAPHY

被引:510
作者
PORATH, J [1 ]
机构
[1] BIOMED CTR, CTR BIOCHEM SEPARAT, S-75123 UPPSALA, SWEDEN
关键词
D O I
10.1016/1046-5928(92)90001-D
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The introduction of immobilized metal ion affinity chromatography, directed toward specific protein side chains, has opened a new dimension in protein purification. This review covers the principles and practice of IMAC that can be performed under very mild, nondenaturing conditions. IMAC is particularly suitable for preparative group fractionation of complex extracts and biofluids, but can also be used in high-performance mode: "HP-IMAC." Single-step purifications of 1000-fold or more may allow isolation of a particular protein from crude extracts on a milligram or gram scale. With respect to separation efficiency, IMAC compares well with biospecific affinity chromatography, and the immobilized metal ion ligand complexes are more likely to withstand wear and tear than are antibodies or enzymes. The enormous potential of IMAC and related metal affinity techniques is only in the initial stages of being explored and exploited. Synthesis of IMA adsorbents, and various modes of performing IMAC are discussed and exemplified with selected applications. Advantages and disadvantages are listed. Effective means of counteracting the few undesirable effects that can occur are suggested. © 1992.
引用
收藏
页码:263 / 281
页数:19
相关论文
共 75 条
[1]   ISOLATION OF PHOSPHOPROTEINS BY IMMOBILIZED METAL (FE-3+) AFFINITY-CHROMATOGRAPHY [J].
ANDERSSON, L ;
PORATH, J .
ANALYTICAL BIOCHEMISTRY, 1986, 154 (01) :250-254
[2]  
ANDERSSON L, 1988, ISI ATLAS-BIOCHEM, V1, P318
[3]  
Andersson L, 1991, Bioseparation, V2, P15
[4]   METAL-AFFINITY SEPARATIONS - A NEW DIMENSION IN PROTEIN PROCESSING [J].
ARNOLD, FH .
BIO-TECHNOLOGY, 1991, 9 (02) :151-156
[5]   INTERACTION OF PROTEINS WITH IMMOBILIZED CU2+ - QUANTITATION OF ADSORPTION CAPACITY, ADSORPTION-ISOTHERMS AND EQUILIBRIUM-CONSTANTS BY FRONTAL ANALYSIS [J].
BELEW, M ;
YIP, TT ;
ANDERSSON, L ;
PORATH, J .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :197-206
[6]   HIGH-PERFORMANCE ANALYTICAL APPLICATIONS OF IMMOBILIZED METAL-ION AFFINITY-CHROMATOGRAPHY [J].
BELEW, M ;
YIP, TT ;
ANDERSSON, L ;
EHRNSTROM, R .
ANALYTICAL BIOCHEMISTRY, 1987, 164 (02) :457-465
[7]   IMMOBILIZED METAL-ION AFFINITY-CHROMATOGRAPHY - EFFECT OF SOLUTE STRUCTURE, LIGAND DENSITY AND SALT CONCENTRATION ON THE RETENTION OF PEPTIDES [J].
BELEW, M ;
PORATH, J .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (02) :333-354
[8]   METAL CHELATE AFFINITY-CHROMATOGRAPHY OF THE DOLICHOS-BIFLORUS SEED LECTIN AND ITS SUBUNITS [J].
BORREBAECK, CAK ;
LONNERDAL, B ;
ETZLER, ME .
FEBS LETTERS, 1981, 130 (02) :194-196
[9]  
CHAGA G, 1989, BIOTECHNOL APPL BIOC, V11, P424
[10]  
CHIECZ RM, 1990, METHOD ENZYMOL, V182, P417