COMPUTER-BASED QUALITY ASSESSMENT OF HOSPITAL CAPILLARY BLOOD-GLUCOSE MONITORING

被引:12
作者
PHILLIPOU, G
FARRANT, RK
PHILLIPS, PJ
机构
[1] Endocrine and Diabetes Department, Queen Elizabeth Hospital, Woodville
关键词
Capillary blood glucose; Extra‐laboratory analysis; Memory glucose meter; Microcomputer; Quality control;
D O I
10.1111/j.1464-5491.1990.tb01376.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A quality control (QC) programme to continually monitor the reliability of hospital ward capillary blood glucose levels has been developed based on a memory blood glucose meter interfaced to a portable microcomputer. Over a 38‐week period some 12 500 ward QC tests were performed by approximately 200 accredited operators. Although the mean weekly coefficients of variation were all less than 15%, there was a marked variation between wards, with the frequency of testing of patients the major factor influencing reliability. However an external laboratory‐based QC programme suggested a high degree of proficiency which was not achieved by any ward on internal QC assessment. 1990 Diabetes UK
引用
收藏
页码:234 / 237
页数:4
相关论文
共 12 条
[1]  
Ting C., Nanjii AA., Evaluation of the quality of the blood glucose level in a teaching hospital, Can Med Assoc J, 138, pp. 23-26, (1988)
[2]  
Hamilton AD, Allen KR, Waters AK., The introduction of a quality assessment scheme for extra‐laboratory blood glucose analysis, Diabetic Med, 6, pp. 444-447, (1989)
[3]  
Sideman K., Padilla B., Huff TA, Stachura ME., Capillary blood glucose monitoring: a comparison of two hospital programs, Diabetes Educ, 14, pp. 223-226, (1989)
[4]  
Lawrence PA, Dowe MC, Perry EK, Strong S., Samsa GP., Accuracy of nurses in performing capillary blood glucose monitoring, Diabetes Care, 12, pp. 298-301, (1989)
[5]  
Innanen VT, Korogyi N., Ambus T., A practical approach to the bedside use of glucose monitoring: a 15 month experience, Can J Med Technol, 50, pp. 146-151, (1988)
[6]  
Potter DM, Carrick C., Baldwin C., Krieg AF., Quality control of nurse‐performed bedside glucose measurement. How to assess nurse performance (Abstract), Diabetes, 37, (1988)
[7]  
Onishi R., Frank H., Vogelsang J., Skaggs B., Accuracy of and nursing attitudes towards hospital glucose meters (Abstract), Diabetes, 37, (1988)
[8]  
Ladenson JH, Goldstein D., Greene D., Steffes MW., Panel discussion II: Home/hospital monitoring of blood glucose, Clin Chem, 32, (1986)
[9]  
Healy MJR., Outliers in clinical chemistry quality‐control schemes, Clin Chem, 25, pp. 675-677, (1979)
[10]  
Cardone MJ., Detection and determination of error in analytical methodology. Part I. In the method verification program review, J Assoc Off Anal Chem, 66, pp. 1257-1282, (1983)