Locking plates in distal humerus fractures: study of 43 patients

被引:6
作者
Gupta, Rakesh Kumar [1 ]
Gupta, Vinay [2 ]
Marak, Dickey Richard [1 ]
机构
[1] Pt BD Sharma Post Grad Inst Med Sci, Dept Orthopaed Phys Med Paraplegia & Rehabil, Rohtak 124001, Haryana, India
[2] Fortis Healthcare Mohali, Dept Orthopaed, Ludhiana 141002, Punjab, India
关键词
Humerus; Fractures; bone; Bone plates; Fracture fixation; internal;
D O I
10.3760/cma.j.issn.1008-1275.2013.04.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal humerus fractures. Methods: Forty-three consecutive patients with articular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29males and 11 females with an average age of 38.4 years (18-73 years). Clinical and radiological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks). The average follow-up was 12 months (10-18 months). Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%). One patient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking plate system is useful in providing stable fixation for complex distal articular fracture and facilitating early post-operative rehabilitation. The low rate of implant failure in the present study indicates that the technique is promising and warrants further investigation.
引用
收藏
页码:207 / 211
页数:5
相关论文
共 24 条
[1]  
Chi-Fat Chan, 2009, Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi, V23, P1285
[2]   Surgical treatment of intra-articular fractures of the distal part of the humerus [J].
Doornberg, Job N. ;
van Duijn, Pleun J. ;
Linzel, Durk ;
Ring, David C. ;
Zurakowski, David ;
Marti, Rene K. ;
Kloen, Peter .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (07) :1524-1532
[3]   Functional outcome of AO type C distal humeral fractures [J].
Gofton, WT ;
MacDermid, JC ;
Patterson, SD ;
Faber, KJ ;
King, GJW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (02) :294-308
[4]   Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system [J].
Greiner, S. ;
Haas, N. P. ;
Bail, H. J. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (07) :723-729
[5]   Intercondylar fractures of the distal humerus in adults: a critical analysis of 55 cases [J].
Gupta, R ;
Khanchandani, P .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (06) :511-515
[6]   The results of open reduction and internal fixation in elderly patients with severe fractures of the distal humerus: A critical analysis of the results [J].
Huang, TL ;
Chiu, FY ;
Chuang, TY ;
Chen, TH .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (01) :62-69
[7]   Custom AO small T plate for transcondylar fractures of the distal humerus in the elderly [J].
Imatani, J ;
Ogura, T ;
Morito, Y ;
Hashizume, H ;
Inoue, H .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (06) :611-615
[8]  
Jacobson S R, 1997, J South Orthop Assoc, V6, P241
[9]  
JUPITER JB, 1992, ORTHOPEDICS, V15, P825
[10]   The Management of Nonunion and Malunion of the Distal Humerus-A 30-Year Experience [J].
Jupiter, Jesse B. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (10) :742-750