DETERMINATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH USE OF BIPHASIC SPIN-ECHO MR IMAGING - COMPARISON WITH CINE MR

被引:47
作者
CAPUTO, GR [1 ]
SUZUKI, JI [1 ]
KONDO, C [1 ]
CHO, H [1 ]
QUAIFE, RA [1 ]
HIGGINS, CB [1 ]
PARKER, DL [1 ]
机构
[1] UNIV UTAH,LATTER DAY ST HOSP,DEPT MED INFORMAT,SALT LAKE CITY,UT 84143
关键词
Heart; ejection fraction; function; MR studies; 524.1214; ventricles; volume; Magnetic resonance (MR); cine study;
D O I
10.1148/radiology.177.3.2243988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, the authors compared a new rapid spin-echo magnetic resonance (MR) imaging method, biphasic MR, with cine MR in the determination of left ventricular volume and mass in healthy volunteers. Biphasic spin-echo MR images covering the entire heart were obtained with use of the electrocardiogram R wave and the downslope of the T wave at both end diastole and end systole, respectively. Biphasic MR-determined values correlated well with small standard errors of the estimate (end-diastolic volume = 7.82 cm3, end-systolic volume = 3.35 cm3, end-diastolic mass = 10.20 g, end-systolic mass = 10.08 g, ejection fraction = 2.62%) and were more reproducible. Cine MR-defined end-systolic volume was significantly larger (P < .01) and ejection fraction was significantly smaller (P < .005) than biphasic MR-determined values probably because of the uncertainty in isolating end systole with cine MR. Left ventricular volumes, mass, and ejection fraction are more accurately and reproducibly quantified in a more time-efficient manner with use of biphasic MR than with cine MR because of its significantly shorter image acquisition and reconstruction times.
引用
收藏
页码:773 / 777
页数:5
相关论文
共 26 条
[1]  
BIRD BF, 1985, AM J CARDIOL, V55, P1440
[2]   SELECTION OF OPTIMUM CINERADIOGRAPHIC FRAME RATE - RELATION TO ACCURACY OF CARDIAC MEASUREMENTS [J].
BOVE, AA ;
ZISKIN, MC ;
FREEMAN, E ;
GIMENEZ, JL ;
LYNCH, PR .
INVESTIGATIVE RADIOLOGY, 1970, 5 (05) :329-&
[3]   NONINVASIVE EVALUATION OF GLOBAL LEFT-VENTRICULAR FUNCTION WITH USE OF CINE NUCLEAR MAGNETIC-RESONANCE [J].
BUSER, PT ;
AUFFERMANN, W ;
HOLT, WW ;
WAGNER, S ;
KIRCHER, B ;
WOLFE, C ;
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1294-1300
[4]   MAGNETIC-RESONANCE IMAGING STRATEGIES FOR HEART STUDIES [J].
CROOKS, LE ;
BARKER, B ;
CHANG, H ;
FEINBERG, D ;
HOENNINGER, JC ;
WATTS, JC ;
MITSUAKI, A ;
KAUFMAN, L ;
SHELDON, PE ;
BOTVINICK, E ;
HIGGINS, CB .
RADIOLOGY, 1984, 153 (02) :459-465
[5]   MAGNETIC-RESONANCE IMAGING OF THE HEART USING IMAGE PLANES ORIENTED TO CARDIAC AXES - EXPERIENCE WITH 100 CASES [J].
DINSMORE, RE ;
WISMER, GL ;
MILLER, SW ;
THOMPSON, R ;
JOHNSTON, DL ;
LIU, P ;
OKADA, RD ;
SAINI, S ;
BRADY, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (06) :1177-1183
[6]   COMPARISON OF MAGNETIC-RESONANCE IMAGING AND ECHOCARDIOGRAPHY IN DETERMINATION OF CARDIAC DIMENSIONS IN NORMAL SUBJECTS [J].
FRIEDMAN, BJ ;
WATERS, J ;
KWAN, OL ;
DEMARIA, AN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (06) :1369-1376
[7]   REPRODUCIBILITY OF LEFT-VENTRICULAR VOLUMES BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
GORDON, EP ;
SCHNITTGER, I ;
FITZGERALD, PJ ;
WILLIAMS, P ;
POPP, RL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (03) :506-513
[8]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[9]  
HAMILTON GW, 1987, NUCLEAR CARDIOLOGY S, P75
[10]  
Higgins C B, 1988, Int J Card Imaging, V3, P21, DOI 10.1007/BF01801641