NON-UNIFORM ATTENUATION AND SCATTER CORRECTION IN SPECT

被引:14
|
作者
SINGH, M
HORNE, M
MANEVAL, D
AMARTEY, J
BRECHNER, R
机构
[1] Univ of Southern California, Los, Angeles, CA, USA, Univ of Southern California, Los Angeles, CA, USA
关键词
BIOMEDICAL ENGINEERING - Computerized Tomography - GAMMA RAYS - Attenuation - IMAGE PROCESSING - Reconstruction - PHOTONS - Scattering;
D O I
10.1109/23.12829
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using a large test object containing an asymmetrical distribution of Tc-99m activity and having nonuniform attenuation, techniques have been developed and evaluated to correct for attenuation and scatter in the object in conjunction with a filtered backprojection reconstruction algorithm. A weighted-backprojection approach whereby corrections are applied to each pixel from each angle of view was used to correct for attenuation. Using a germanium detector to sample the energy spectrum of emitted radiation, an optimal method was devised to subtract scatter counts from the photopeak counts of a scintillation camera before reconstruction. SPECT (single-photon-emission computed tomography) images of the test object were evaluated to validate the correction approaches.
引用
收藏
页码:767 / 771
页数:5
相关论文
共 50 条
  • [31] Impact of attenuation correction, scatter correction and resolution recovery an cardiac SPECT
    Keng, F
    Chang, SM
    Salfity, M
    Verant, MS
    CIRCULATION, 1999, 100 (18) : 312 - 312
  • [32] Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation
    Beekman, FJ
    de Jong, HWAM
    Slijpen, ETP
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08): : N183 - N192
  • [33] Scatter, attenuation and detector response correction in brain SPECT.
    Shinohara, H
    Matsuoka, M
    Yamamoto, T
    Niio, Y
    Kuniyasu, Y
    Hashimoto, T
    Takahashi, M
    Yokoi, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 302P - 302P
  • [34] SCATTER IMAGING WITH EXTERNAL SOURCE FOR ATTENUATION CORRECTION OF CARDIAC SPECT
    CHANG, W
    HUANG, G
    ALDOOHAN, S
    PAWLOWSKI, J
    LONCARIC, S
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P195 - P195
  • [35] Comparison of Methods of Attenuation and Scatter Correction in Brain Perfusion SPECT
    Hayashi, Masuo
    Deguchi, Jun
    Utsunomiya, Keita
    Yamada, Makoto
    Komori, Tsuyoshi
    Takeuchi, Masayasu
    Kanna, Kensei
    Narabayashi, Isamu
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2005, 33 (04) : 224 - 229
  • [36] Non-Uniform Attenuation Correction of SPECT Images: The Effect of Transmission Data Acquisition Time on Image Contrast and Signal to Noise Ratio
    Perisinakis, K.
    Damilakis, J.
    Stathaki, M.
    Karkavitsas, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S256 - S257
  • [37] A comparison of two iterative reconstruction methods with non-uniform attenuation correction.
    Kauppinen, TA
    Alenius, ST
    Koskinen, MO
    Kuikka, JT
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 301P - 301P
  • [38] Fully 3D iterative scatter compensation in non-uniform attenuating media for SPECT.
    Beekman, FJ
    denHarder, JM
    Viergever, MA
    vanRijk, PP
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 979 - 979
  • [39] SPECT Reconstruction with Non-uniform Attenuation from Highly Under-sampled Projection Data
    Li, Cuifen
    Wen, Junhai
    Zhang, Kangping
    Shi, Donghao
    Dong, Haixiang
    Li, Wenxiao
    Liang, Zhengrong
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [40] Image reconstruction for discontinuous objects with half-data knowledge in SPECT with non-uniform attenuation
    Sidky, EY
    Pan, XC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2919 - 2922