NON-UNIFORM ATTENUATION AND SCATTER CORRECTION IN SPECT

被引:14
|
作者
SINGH, M
HORNE, M
MANEVAL, D
AMARTEY, J
BRECHNER, R
机构
[1] Univ of Southern California, Los, Angeles, CA, USA, Univ of Southern California, Los Angeles, CA, USA
关键词
BIOMEDICAL ENGINEERING - Computerized Tomography - GAMMA RAYS - Attenuation - IMAGE PROCESSING - Reconstruction - PHOTONS - Scattering;
D O I
10.1109/23.12829
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using a large test object containing an asymmetrical distribution of Tc-99m activity and having nonuniform attenuation, techniques have been developed and evaluated to correct for attenuation and scatter in the object in conjunction with a filtered backprojection reconstruction algorithm. A weighted-backprojection approach whereby corrections are applied to each pixel from each angle of view was used to correct for attenuation. Using a germanium detector to sample the energy spectrum of emitted radiation, an optimal method was devised to subtract scatter counts from the photopeak counts of a scintillation camera before reconstruction. SPECT (single-photon-emission computed tomography) images of the test object were evaluated to validate the correction approaches.
引用
收藏
页码:767 / 771
页数:5
相关论文
共 50 条
  • [1] SCATTER CORRECTION IN SPECT USING NON-UNIFORM ATTENUATION DATA
    MUKAI, T
    LINKS, JM
    DOUGLASS, KH
    WAGNER, HN
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (10): : 1129 - 1140
  • [2] IMPROVEMENT OF QUANTITATION IN SPECT - ATTENUATION AND SCATTER CORRECTION USING NON-UNIFORM ATTENUATION DATA
    MUKAI, T
    TORIZUKA, K
    DOUGLASS, KH
    WAGNER, HN
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P91 - P91
  • [3] Non-uniform scatter and attenuation correction for brain spect without transmission imaging.
    Stodilka, RZ
    Kemp, BJ
    Kertesz, A
    Prato, FS
    Kuhl, DC
    Nicholson, RL
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 297P - 297P
  • [4] Evaluation of non-uniform attenuation and scatter-correction in bone spect of the cervical, thoracic and lumbar spine.
    Licho, R
    Wells, RG
    King, MA
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 328P - 328P
  • [5] Is non-uniform attenuation correction necessary for clinical brain perfusion SPECT?
    Van Laere, KJ
    Audenaert, K
    Versijpt, J
    Koole, M
    Kalmar, A
    Dumont, F
    Dierckx, RA
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 186P - 186P
  • [6] SPECT scatter modelling in non-uniform attenuating objects
    Beekman, FJ
    denHarder, JM
    Viergever, MA
    vanRijk, PP
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06): : 1133 - 1142
  • [7] Analytical reconstruction for helical cone-beam SPECT with non-uniform attenuation correction
    Huang, Qiu
    Zeng, Gengsheng L.
    Gullberg, Grant T.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1856 - 1859
  • [8] Impact of non-uniform attenuation correction and scatter correction on the diagnostic accuracy of myocardial SPECT for the detection of coronary artery disease (CAD) - A prospective study.
    Forster, M
    Kluge, R
    Seese, A
    Sabri, O
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 49P - 49P
  • [9] Super resolution SPECT reconstruction with non-uniform attenuation
    Yan, Ziye
    Lu, Yao
    Wen, Junhai
    Li, Cuifen
    COMPUTERS IN BIOLOGY AND MEDICINE, 2012, 42 (06) : 651 - 656
  • [10] Improvement of brain perfusion SPET using iterative reconstruction with scatter and non-uniform attenuation correction
    Tomi Kauppinen
    Matti O. Koskinen
    Sakari Alenius
    Esko Vanninen
    Jyrki T. Kuikka
    European Journal of Nuclear Medicine, 2000, 27 : 1380 - 1386