Plan quality and delivery time comparisons between volumetric modulated arc therapy and intensity modulated radiation therapy for scalp angiosarcoma: A planning study

被引:16
|
作者
Kai, Yudai [1 ]
Toya, Ryo [2 ,3 ]
Saito, Tetsuo [2 ]
Kuraoka, Akiko [1 ]
Shimohigashi, Yoshinobu [1 ]
Nakaguchi, Yuji [1 ]
Maruyama, Masato [1 ]
Murakami, Ryuji [4 ]
Yamashita, Yasuyuki [5 ]
Oya, Natsuo [2 ]
机构
[1] Kumamoto Univ Hosp, Dept Radiol Technol, Kumamoto, Japan
[2] Kumamoto Univ Hosp, Dept Radiat Oncol, Kumamoto, Japan
[3] Univ Wisconsin, Dept Human Oncol, Sch Med & Publ Hlth, Madison, WI USA
[4] Kumamoto Univ, Dept Med Imaging, Fac Life Sci, Kumamoto, Japan
[5] Kumamoto Univ Hosp, Dept Diagnost Radiol, Kumamoto, Japan
来源
JOURNAL OF MEDICAL RADIATION SCIENCES | 2018年 / 65卷 / 01期
关键词
Angiosarcoma; intensity modulated radiation therapy; scalp irradiation; volumetric modulated arc therapy; X-ray Voxel Monte Carlo algorithm;
D O I
10.1002/jmrs.239
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Due to its spherical surface, scalp angiosarcoma requires careful consideration for radiation therapy planning and dose delivery. Herein, we investigated whether volumetric modulated arc therapy (VMAT) is superior to intensity modulated radiation therapy (IMRT) in terms of the plan quality and delivery time. Methods: Three different coplanar treatment plans were created for four patients, comprising a two-arc VMAT plan as well as 5-field and 9-field IMRT plans with 6 MV beams. The X-ray Voxel Monte Carlo algorithm was employed for dose calculation. A radiation therapy dose of 60 Gy was prescribed to the planning target volume (PTV) in 30 fractions. The homogeneity indexes (HIs) and conformity indexes (CIs) of the PTV, organs at risk (OARs) doses and delivery times were calculated and compared. Results: For the VMAT, 5-field and 9-field IMRT plans, the mean HIs were 0.14, 0.16 and 0.15; CIs(100%) were 0.63, 0.61 and 0.64; CIs(98%) were 0.72, 0.66 and 0.70 and CIs(95%) were 0.74, 0.67 and 0.71 respectively. All mean dose parameters of the VMAT and 9-field IMRT plans for the brain were equal to or lower than those of the 5-field IMRT plan. For the 5-field IMRT plan, the dose constraints for the left lens were not satisfied in two patients. The mean delivery times were 3.3, 11.1 and 14.7 min for the VMAT, 5-field and 9-field IMRT plans respectively. Conclusion: The VMAT plan quality is comparable to that of 9-field IMRT, with a reduced delivery time. Therefore, VMAT represents a valuable, sophisticated irradiation technique for treating scalp angiosarcoma.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 50 条
  • [21] Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer
    Li, Zhiping
    Zeng, Jianshuang
    Wang, Zi
    Zhu, Hong
    Wei, Yuquan
    ONCOLOGY LETTERS, 2014, 8 (04) : 1427 - 1434
  • [22] Radiotherapy for unresectable sinonasal cancers: Dosimetric comparison of intensity modulated radiation therapy with coplanar and non-coplanar volumetric modulated arc therapy
    Orlandi, Ester
    Giandini, Tommaso
    Iannacone, Eva
    De Ponti, Elena
    Carrara, Mauro
    Mongioj, Valeria
    Stucchi, Claudio
    Tana, Silvia
    Bossi, Paolo
    Licitra, Lisa
    Fallai, Carlo
    Pignoli, Emanuele
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) : 260 - 266
  • [23] Multi-institutional comparison of computer-based independent dose calculation for intensity modulated radiation therapy and volumetric modulated arc therapy
    Kamima, Tatsuya
    Baba, Hiromi
    Takahashi, Ryo
    Yamashita, Mikiko
    Sugawara, Yasuharu
    Kawai, Daisuke
    Yamamoto, Toshijiro
    Satou, Aya
    Tachibana, Hidenobu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 72 - 81
  • [24] SmartArc-based volumetric modulated arc therapy for endometrial cancer: a dosimetric comparison with helical tomotherapy and intensity-modulated radiation therapy
    Yang, Ruijie
    Wang, Junjie
    Xu, Shouping
    Li, Hua
    BMC CANCER, 2013, 13
  • [25] Cardiac substructure exposure in breast radiotherapy: a comparison between intensity modulated proton therapy and volumetric modulated arc therapy
    Loap, Pierre
    Tkatchenko, Nicolas
    Goudjil, Farid
    Ribeiro, Madison
    Baron, Brian
    Fourquet, Alain
    Kirova, Youlia
    ACTA ONCOLOGICA, 2021, 60 (08) : 1038 - 1044
  • [26] Randomized algorithms for high quality treatment planning in volumetric modulated arc therapy
    Yang, Yu
    Dong, Bin
    Wen, Zaiwen
    INVERSE PROBLEMS, 2017, 33 (02)
  • [27] A prospective trial of volumetric intensity-modulated arc therapy vs conventional intensity modulated radiation therapy in advanced head and neck cancer
    Fung-Kee-Fung, Simon D.
    Hackett, Rachel
    Hales, Lee
    Warren, Graham
    Singh, Anurag K.
    WORLD JOURNAL OF CLINICAL ONCOLOGY, 2012, 3 (04): : 57 - 62
  • [28] Volumetric modulated arc therapy in differentiated thyroid cancer: a treatment planning comparison with intensity-modulated radiotherapy
    Chan, Wing Lok
    Ng, Sherry C. Y.
    Law, Martin W. M.
    Lee, Victor H. F.
    Wan, K. Y.
    Leung, T. W.
    JOURNAL OF RADIATION ONCOLOGY, 2015, 4 (04) : 417 - 422
  • [29] SmartArc-based volumetric modulated arc therapy for endometrial cancer: a dosimetric comparison with helical tomotherapy and intensity-modulated radiation therapy
    Ruijie Yang
    Junjie Wang
    Shouping Xu
    Hua Li
    BMC Cancer, 13
  • [30] Evaluation of Healthy Tissue Dose at Different Regions between Volumetric-Modulated Arc Therapy and Intensity-Modulated Radiation Therapy Plans in the Treatment of Various Cancers
    Krishnan, Jayapalan
    Rao, Suresh
    Hegde, Sanath
    Shetty, Jayarama
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (03) : 213 - 221