IMPROVED DETECTION OF SILENT CARDIAC ISCHEMIA WITH A 12-LEAD PORTABLE MICROPROCESSOR-DRIVEN REAL-TIME ELECTROCARDIOGRAPHIC MONITOR

被引:5
|
作者
THOMPSON, RC
MACKEY, DC
LANE, GE
BLACKSHEAR, JL
SHINE, TSJ
EBENER, MK
SAFFORD, RE
机构
[1] MAYO CLIN JACKSONVILLE,DIV CARDIOVASC DIS & INTERNAL MED,JACKSONVILLE,FL 32224
[2] MAYO CLIN JACKSONVILLE,DEPT ANESTHESIOL,JACKSONVILLE,FL 32224
关键词
D O I
10.4065/70.5.434
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare a microprocessor-driven real-time 12-lead electrocardiographic monitoring device with Holter monitoring for detection of ischemia. Design: Electrocardiographic monitoring was conducted in 110 patients at bed rest or undergoing surgical procedures. Material and Methods: In three groups of patients, simultaneous monitoring with a 12-lead realtime device and a 2-channel Holter system was performed to detect ischemic episodes, The differences in the number of ischemic events and the total time of ischemia revealed by the two devices were analyzed statistically. Results: In patients with coronary artery disease, more ischemic ST-segment shifts were detected by the 12-1ead device than by Holter monitoring (44 versus 16 events; P<0.05). Total time of ischemia was also greater with the 12-lead device (879 versus 273 minutes; P<0.05). Ischemia was detected by both techniques in 6 patients, only by the 12-lead device in 12, and only by Holter monitoring in 1, Neither device detected ischemia in control subjects, The 12-lead device had an advantage in detecting inferior ischemia, and it identified an additional 13 patients with unstable angina who had changes in T-wave polarity but did not exhibit ST-segment shifts. Conclusion: The 12-lead real-time electrocardiographic monitoring device is superior to Holter monitoring in detecting and facilitating real-time identification of myocardial ischemia in patients at bed rest.
引用
收藏
页码:434 / 442
页数:9
相关论文
共 39 条
  • [21] SILENT AND SYMPTOMATIC ISCHEMIA AFTER ANGIOPLASTY - DETECTION WITH CONTINUOUS AND REAL-TIME ST SEGMENT MONITORING
    KRUCOFF, MW
    POPE, JE
    WAGNER, GS
    ADAMS, IM
    BOTTNER, RK
    SATLER, LF
    AHMED, SW
    RACKLEY, CE
    KENT, KM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A68 - A68
  • [22] CONTINUOUSLY UPDATED 12-LEAD ST SEGMENT RECOVERY ANALYSIS FOR REAL-TIME DETECTION OF REPERFUSION AND REOCCLUSION - INTEROBSERVER AND INTRAOBSERVER VARIABILITY OF THE DUKE METHOD
    KRUCOFF, MW
    VELDKAMP, RF
    TROLLINGER, KM
    KEELER, G
    SAWCHAK, ST
    BENGTSON, JR
    CIRCULATION, 1992, 86 (04) : 857 - 857
  • [23] A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water
    Ryu, Byunghoon
    Zhuang, Wen
    Jang, Hyun-June
    Gao, Zhenwei
    Wang, Yuqin
    Chen, Junhong
    ENVIRONMENTAL SCIENCE-NANO, 2025, 12 (03)
  • [24] Portable microfluidic plasmonic chip for fast real-time cardiac troponin I biomarker thermoplasmonic detection
    Campu, Andreea
    Muresan, Ilinca
    Potara, Monica
    Lazar, Diana Raluca
    Lazar, Florin-Leontin
    Cainap, Simona
    Olinic, Dan Mircea
    Maniu, Dana
    Astilean, Simion
    Focsan, Monica
    JOURNAL OF MATERIALS CHEMISTRY B, 2024, 12 (04) : 962 - 972
  • [25] CONTINUOUS 12-LEAD ST-SEGMENT RECOVERY ANALYSIS IN THE TAMI 7 STUDY - PERFORMANCE OF A NONINVASIVE METHOD FOR REAL-TIME DETECTION OF FAILED MYOCARDIAL REPERFUSION
    KRUCOFF, MW
    CROLL, MA
    POPE, JE
    GRANGER, CB
    OCONNOR, CM
    SIGMON, KN
    WAGNER, BL
    RYAN, JA
    LEE, KL
    KEREIAKES, DJ
    SAMAHA, JK
    WORLEY, SJ
    ELLIS, SG
    WALL, TC
    TOPOL, EJ
    CALIFF, RM
    CIRCULATION, 1993, 88 (02) : 437 - 446
  • [26] Efficacy of real-time tele-transmission system of 12-lead electrocardiogram for myocardial hemorrhage patients on the first-aid
    Wang, Jian
    Feng, Shunyi
    Guo, Jinping
    Yang, Long
    Lv, Guangxin
    Li, Yong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (10): : 10468 - 10474
  • [27] DETECTION OF SILENT ISCHEMIA DURING INDUCTION OF ANESTHESIA FOR CORONARY-BYPASS SURGERY BY REAL-TIME ST MONITORING - INCIDENCE AND SIGNIFICANCE
    FREEDMAN, SB
    RAJKUMAR, C
    WALSH, RG
    CLARKE, FB
    THOMSON, DS
    HUGHES, CF
    KELLY, DT
    HARRIS, PJ
    CORONARY ARTERY DISEASE, 1990, 1 (05) : 567 - 571
  • [28] Improved R-wave detection for enhanced cardiac Gating using an MRI-compatible 12-lead ECG and multi-channel analysis
    Zion Tsz Ho Tse
    Charles L Dumoulin
    Gari Clifford
    Michael Jerosch-Herold
    Daniel Kacher
    Raymond Kwong
    William Gregory Stevenson
    Ehud Jeruham Schmidt
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [29] G-Quadruplex and DNAzyme dual-driven DNA detection system for real-time quantitative detection of environmental lead ions
    Liu, Xinru
    Zhang, Yue
    Fan, Liangping
    Tang, Hehe
    Xu, Keying
    Xu, Jiafeng
    Liu, Gang
    Chang, Wei
    Liu, Xiaoyan
    Wang, Hua
    Wang, Jie
    JOURNAL OF HAZARDOUS MATERIALS, 2025, 489
  • [30] Effect of a real-time tele-transmission system of 12-lead electrocardiogram on the first-aid for athletes with ST-elevation myocardial infarction
    Zhang, Huan
    Song, Donghan
    An, Lina
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2016, 29 (03) : 1059 - 1062