A COMPARISON OF EXPANDED-BED GAC REACTOR DESIGNS FOR THE TREATMENT OF REFRACTORY INHIBITORY WASTEWATERS

被引:10
作者
FOX, P [1 ]
SUIDAN, MT [1 ]
机构
[1] UNIV CINCINNATI,DEPT CIVIL & ENVIRONM ENGN,CINCINNATI,OH 45221
关键词
INHIBITORY; GRANULAR ACTIVATED CARBON; ETHYLPHENOL; ACETATE; METHANE; ADSORPTION; BIODEGRADATION;
D O I
10.1016/0043-1354(93)90139-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A hybrid granular activated carbon (GAC) expanded-bed reactor designed to decouple biological removal from physical removal and a GAC expanded-bed reactor were studied under similar operating conditions. The hybrid GAC reactor consisted of a GAC expanded-bed reactor which was retrofitted with a GAC adsorber containing 11.1% of the total GAC mass in the system. A synthetic wastewater composed of acetate and 3-ethylphenol (3-EP) at influent concentrations of 5 g acetate/l and 1.5-2.5 g 3-EP/l was used at COD loadings of 18.7 23.8 kg COD/m3. Partial replacement of GAC in both reactors facilitated the physical removal of 3-EP. GAC was replaced from only the side adsorber in the hybrid GAC reactor while GAC was replaced directly from the GAC reactor. Previous studies indicated that increasing GAC replacement rates washed biomass out of the GAC reactor while the hybrid reactor was resilient to changes in operating conditions. This study compared the reactors while maintaining a constant GAC replacement rate with an increasing influent loading of the inhibitory/refractory compound, 3-EP. The performance of the GAC reactor deteriorated with increasing 3-EP loading rates until reactor failure occurred due to inhibition. The hybrid reactor responded to increases in the influent 3-EP loading rate with greater than 60% biological removal of 3-EP and only minor changes in effluent quality. Termination of GAC replacement in the hybrid reactor allowed for almost complete biological removal of 3-EP in the hybrid reactor. The resilience of the hybrid GAC reactor was attributed to the accumulation and maintenance of a stable microbial population capable of degrading an inhibitory substrate.
引用
收藏
页码:769 / 776
页数:8
相关论文
共 12 条
  • [1] BLUM DJW, 1986, J WATER POLLUT CON F, V58, P122
  • [2] BATCH TESTS TO DETERMINE ACTIVITY DISTRIBUTION AND KINETIC-PARAMETERS FOR ACETATE UTILIZATION IN EXPANDED-BED ANAEROBIC REACTORS
    FOX, P
    SUIDAN, MT
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1990, 56 (04) : 887 - 894
  • [3] A COMPARISON OF MEDIA TYPES IN ACETATE FED EXPANDED-BED ANAEROBIC REACTORS
    FOX, P
    SUIDAN, MT
    BANDY, JT
    [J]. WATER RESEARCH, 1990, 24 (07) : 827 - 835
  • [4] HYBRID EXPANDED-BED GAC REACTOR FOR TREATING INHIBITORY WASTEWATERS
    FOX, P
    SUIDAN, MT
    PFEFFER, JT
    BANDY, JT
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1990, 116 (03): : 438 - 453
  • [5] Herbert D., 1971, METHODS MICROBIOLOGY
  • [6] BIOTREATMENT OF S-TRIAZINE-CONTAINING WASTE-WATER IN A FLUIDIZED-BED REACTOR
    HOGREFE, W
    GROSSENBACHER, H
    COOK, AM
    HUTTER, R
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1986, 28 (10) : 1577 - 1581
  • [7] KHAN KA, 1981, J WATER POLLUT CON F, V53, P1519
  • [8] MCCARTY PL, 1971, ADV CHEM SERIES, V105
  • [9] NAKHLA GF, 1988, WATER SCI TECHNOL, V21, P167
  • [10] SUIDAN MT, 1983, J WATER POLLUT CON F, V55, P1263