CT-GUIDED BONE-BIOPSY PERFORMED BY MEANS OF A COAXIAL BIOPSY SYSTEM WITH AN ECCENTRIC DRILL

被引:29
作者
AHLSTROM, KH
ASTROM, KGO
机构
[1] Department of Diagnostic Radiology, Akademiska Sjukhuset, University Hospital
关键词
BONE MARROW; BIOPSY; BONE NEOPLASMS; DIAGNOSIS; BONES; INTERVENTIONAL PROCEDURES; TECHNOLOGY;
D O I
10.1148/radiology.188.2.8327713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Thirty-seven consecutive bone biopsies guided with computed tomography were performed in 32 patients by use of three different techniques to penetrate cortical bone and gain access to the lesion. The following instruments were used: a thin bone biopsy needle (12 biopsies), a conventional drill with an outer cannula (six biopsies), and a coaxial biopsy system that consists of a drill with an eccentric tip and an outer cannula (19 biopsies). This eccentric drill makes a hole in the bone larger than the diameter of the cannula and thereby makes it easy to advance the cannula over the drill until the cannula is anchored in the bone. One can then obtain multiple samples through the cannula. The thin bone biopsy needle could not penetrate thick (8 mm thick) cortical bone. The outer cannula was not anchored in the bone when the conventional drill was used. In 16 biopsies, the new coaxial biopsy system penetrated cortical bone with a thickness of 1-8 mm and was anchored there, and lesion samples were obtained through the anchored cannula.
引用
收藏
页码:549 / 552
页数:4
相关论文
共 50 条
  • [21] CT-GUIDED BIOPSY OF SPINE LYTIC LESIONS
    FACCHINETTI, A
    GRIVETTA, MA
    BARUZZI, F
    MINONZIO, G
    MERCURI, A
    ALBERTINI, F
    BONALDI, G
    RIVISTA DI NEURORADIOLOGIA, 1995, 8 (02): : 215 - 221
  • [22] Value of CT-guided biopsy in malignant lymphoma
    Libicher, M
    Nöldge, G
    Radeleff, B
    Gholipur, F
    Richter, GM
    RADIOLOGE, 2002, 42 (12): : 1009 - 1012
  • [23] Pitfalls in CT-guided transthoracic needle biopsy of pulmonary nodules
    Yankelevitz, DF
    Davis, SD
    Chiarella, DA
    Henschke, CI
    RADIOGRAPHICS, 1996, 16 (05) : 1073 - 1084
  • [24] CT-guided transsternal core biopsy of anterior mediastinal masses
    Astrom, KGO
    Ahlstrom, KH
    Magnusson, A
    RADIOLOGY, 1996, 199 (02) : 564 - 567
  • [25] CT-guided transthoracic needle biopsy in the diagnosis of chest tumours
    Cattelani, L
    Campodonico, F
    Rusca, M
    Solli, P
    Carbognani, P
    Spaggiari, L
    DalCorso, HM
    JOURNAL OF CARDIOVASCULAR SURGERY, 1997, 38 (05) : 539 - 542
  • [26] Role of percutaneous CT-guided biopsy in the characterisation of pleural diseases
    Pasha, Iram
    Singh, Anil K.
    Hashim, Zia
    Nath, Alok
    Neyaz, Zafar
    Mishra, Richa
    Agrawal, Vinita
    LUNG INDIA, 2023, 40 (06) : 514 - 520
  • [27] CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: Results with an automated 20-gauge coaxial cutting needle
    Laurent, F
    Latrabe, V
    Vergier, B
    Montaudon, M
    Vernejoux, JM
    Dubrez, J
    CLINICAL RADIOLOGY, 2000, 55 (04) : 281 - 287
  • [28] Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients
    Nour-Eldin, Nour-Eldin A.
    Alsubhi, Mohammed
    Naguib, Nagy N.
    Lehnert, Thomas
    Emam, Ahmed
    Beeres, Martin
    Bodelle, Boris
    Koitka, Karen
    Vogl, Thomas J.
    Jacobi, Volkmar
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1945 - 1952
  • [29] CT-guided needle biopsy of small pulmonary nodules: Value of respiratory gating
    Tomiyama, N
    Mihara, N
    Maeda, M
    Johkoh, T
    Kozuka, T
    Honda, O
    Hamada, S
    Yoshida, S
    Nakamura, H
    RADIOLOGY, 2000, 217 (03) : 907 - 910
  • [30] CT-guided stereotactic brain biopsy using the Kopf stereotactic system
    Troxel, Mark T.
    Vite, Charles H.