ZERO-DEAD-VOLUME PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY

被引:19
|
作者
CEPAS, J [1 ]
SILVA, M [1 ]
PEREZBENDITO, D [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
D O I
10.1021/ac00119a028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, flexible, and inexpensive peroxyoxalate chemiluminescence detection reactor for liquid chromatography is reported, This postcolumn device permits the efficient mixing of the mobile phase and reactants, bis(2,4,6-trichlorophenyl) oxalate and hydrogen peroxide, with a zero dead-volume and the following features: (a) highly flexible optimization of chemical variables affecting the peroxyoxalate chemiluminescence reaction, which can take place outside the chromatographic system; (b) use of high oxidant/oxalate ester concentration ratios, which decrease background emission and increase the signal/noise ratio; and (c) use of large reaction volumes in the detection cell without excessive additional band broadening (the chemiluminescence reaction is very rapid under the selected experimental conditions), The proposed detection system was tested in the high-performance liquid chromatographic determination of polycyclic aromatic hydrocarbons, where it exhibited higher sensitivity (limits of detection in the femtomole range) than existing alternatives.
引用
收藏
页码:4376 / 4379
页数:4
相关论文
共 50 条
  • [21] QUINOXALINONE DERIVATIZATION OF BIOLOGICAL CARBOXYLIC-ACIDS FOR DETECTION BY PEROXYOXALATE CHEMILUMINESCENCE WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SANDMANN, BW
    GRAYESKI, ML
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 653 (02): : 123 - 130
  • [22] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOLLOWED BY PEROXYOXALATE CHEMILUMINESCENCE DETECTION OF ACETYLCHOLINE AND CHOLINE UTILIZING IMMOBILIZED ENZYMES
    HONDA, K
    MIYAGUCHI, K
    NISHINO, H
    TANAKA, H
    YAO, T
    IMAI, K
    ANALYTICAL BIOCHEMISTRY, 1986, 153 (01) : 50 - 53
  • [23] High performance liquid chromatography with peroxyoxalate chemiluminescence detection of synthetic peptide, ebiratide
    Hamachi, Y
    Nakashima, K
    Akiyama, S
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (15) : 2377 - 2387
  • [24] KINETIC-STUDY OF BACKGROUND EMISSION FROM PEROXYOXALATE CHEMILUMINESCENCE REACTION AND APPLICATION TO THE IMPROVEMENT OF DETECTION LIMITS IN LIQUID-CHROMATOGRAPHY
    HANAOKA, N
    TANAKA, H
    NAKAMOTO, A
    TAKADA, M
    ANALYTICAL CHEMISTRY, 1991, 63 (23) : 2680 - 2685
  • [25] LOW DEAD VOLUME COULOMETRIC DETECTOR FOR LIQUID-CHROMATOGRAPHY
    TAKATA, Y
    TAKI, M
    ITO, M
    MURAO, T
    JOURNAL OF CHROMATOGRAPHY, 1985, 332 (SEP): : 117 - 125
  • [26] NOISE AND BACKGROUND IN PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION FOR LIQUID-CHROMATOGRAPHY
    WEINBERGER, R
    MANNAN, CA
    CERCHIO, M
    GRAYESKI, ML
    JOURNAL OF CHROMATOGRAPHY, 1984, 288 (02): : 445 - 450
  • [27] CHEMILUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY - POSSIBILITIES OFFERED BY THE PEROXYOXALATES
    TOD, M
    FARINOTTI, R
    MAHUZIER, G
    ANALUSIS, 1986, 14 (06) : 271 - 280
  • [28] Zero-dead-volume interfaces for two-dimensional electrophoretic separations
    Sydes, Daniel
    Kler, Pablo A.
    Hermans, Martin
    Huhn, Carolin
    ELECTROPHORESIS, 2016, 37 (22) : 3020 - 3024
  • [29] PRIMARY AND SECONDARY AMINE DERIVATIZATION WITH LUMINARIN-1 AND LUMINARIN-2 - SEPARATION BY LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION
    TOD, M
    LEGENDRE, JY
    CHALOM, J
    KOUWATLI, H
    POULOU, M
    FARINOTTI, R
    MAHUZIER, G
    JOURNAL OF CHROMATOGRAPHY, 1992, 594 (1-2): : 386 - 391
  • [30] Determination of tranexamic acid and vitamins by high performance liquid chromatography with peroxyoxalate chemiluminescence detection
    Department of Fundamental Science, College of Science and Engineering, Iwaki Meisei University, Iwaki, Fukushima 970, Japan
    Anal. Sci., SUPPL. (471-474):