ZERO-DEAD-VOLUME PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY

被引:19
作者
CEPAS, J [1 ]
SILVA, M [1 ]
PEREZBENDITO, D [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
D O I
10.1021/ac00119a028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, flexible, and inexpensive peroxyoxalate chemiluminescence detection reactor for liquid chromatography is reported, This postcolumn device permits the efficient mixing of the mobile phase and reactants, bis(2,4,6-trichlorophenyl) oxalate and hydrogen peroxide, with a zero dead-volume and the following features: (a) highly flexible optimization of chemical variables affecting the peroxyoxalate chemiluminescence reaction, which can take place outside the chromatographic system; (b) use of high oxidant/oxalate ester concentration ratios, which decrease background emission and increase the signal/noise ratio; and (c) use of large reaction volumes in the detection cell without excessive additional band broadening (the chemiluminescence reaction is very rapid under the selected experimental conditions), The proposed detection system was tested in the high-performance liquid chromatographic determination of polycyclic aromatic hydrocarbons, where it exhibited higher sensitivity (limits of detection in the femtomole range) than existing alternatives.
引用
收藏
页码:4376 / 4379
页数:4
相关论文
共 20 条
[11]  
LI Q, 1990, FENXI CESHI TONGBAO, V9, P33
[12]   BACKGROUND EMISSION FROM THE PEROXYOXALATE CHEMILUMINESCENCE REACTION IN THE ABSENCE OF FLUOROPHORS [J].
MANN, B ;
GRAYESKI, ML .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1532-1536
[13]   USE OF CE(IV) OXIDIZING-AGENT FOR THE DERIVATIZATION OF POLYCYCLIC AROMATIC-HYDROCARBONS FOR LIQUID-CHROMATOGRAPHY ELECTROCHEMICAL DETECTION [J].
MAZZEO, JR ;
KRULL, IS ;
KISSINGER, PT .
JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2) :585-594
[14]   SUB-PICOMOL CHEMI-LUMINESCENCE DETECTION OF DNS-AMINO ACIDS SEPARATED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH GRADIENT ELUTION [J].
MIYAGUCHI, K ;
HONDA, K ;
IMAI, K .
JOURNAL OF CHROMATOGRAPHY, 1984, 303 (01) :173-176
[15]   EVALUATION OF A THERMAL-DESORPTION GAS-CHROMATOGRAPH MASS-SPECTROMETER - ON-SITE DETECTION OF POLYCHLORINATED-BIPHENYLS AT A HAZARDOUS-WASTE SITE [J].
ROBBAT, A ;
LIU, TY ;
ABRAHAM, BM .
ANALYTICAL CHEMISTRY, 1992, 64 (04) :358-364
[16]   PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN LIQUID-CHROMATOGRAPHY [J].
SIGVARDSON, KW ;
BIRKS, JW .
ANALYTICAL CHEMISTRY, 1983, 55 (03) :432-435
[17]   PEROXYOXALATE CHEMILUMINESCENCE DETECTION WITH CAPILLARY LIQUID-CHROMATOGRAPHY [J].
WEBER, AJ ;
GRAYESKI, ML .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1452-1457
[18]   SOLVENT AND PH EFFECTS ON PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION FOR LIQUID-CHROMATOGRAPHY [J].
WEINBERGER, R .
JOURNAL OF CHROMATOGRAPHY, 1984, 314 (NOV) :155-165
[19]   UNIVERSAL DETECTOR BASED ON MAGNETOOPTICAL ROTATION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
XI, XB ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1991, 63 (05) :490-496
[20]   PROCEDURES FOR THE ENHANCEMENT OF SELECTIVITY IN LIQUID-PHASE CHEMILUMINESCENCE DETECTION [J].
YAN, BL ;
LEWIS, W ;
WORSFOLD, PJ .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :145-155