COMPARISON OF HYDRAZONE DERIVATIVES FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:0
|
作者
UEHARA, N
HIROTA, M
SHIJO, Y
机构
关键词
REVERSED PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; HYDRAZONES; HPLC SELECTIVITIES; METAL CHELATES;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several hydrazones having similar structures and different donating atoms were synthesized and used as precolumn chelating agents of metal chelates for HPLC. The relationship between the HPLC selectivities for metal chelates and the donating atoms of hydrazones was also evaluated. The hydrazones were synthesized from corresponding hydrazines and aldehydes by refluxing in ethanol. Hydrazone chelates was insoluble in water. The chelates were prepared with methanol-water mixture or dimethylformamide-water mixture. Most of the hydrazone chelates had absorption maxima near 400 nm. The eluents were methanol -water mixtures, which contained tetrabutylammonium bromide as necessary. The HPLC selectivities of hydrazones for metal ions were higher than the selectivities of complexation. The tridentate hydrazones gave more chelate peaks than the bidentate hydrazones did. The hydrazones made from 4-phenyl-3-thiosemicarbazide gave more peaks than the hydrazone made from benzoylhydrazine.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 50 条
  • [31] SEPARATION OF CYTOKININS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HOLLAND, JA
    MCKERRELL, EH
    FUELL, KJ
    BURROWS, WJ
    JOURNAL OF CHROMATOGRAPHY, 1978, 166 (02): : 545 - 553
  • [32] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF RETINYL ESTERS
    FURR, HC
    METHODS IN ENZYMOLOGY, 1990, 189 : 85 - 94
  • [33] SEPARATION OF MONOACYLGLYCEROLS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SEMPORE, BG
    BEZARD, JA
    JOURNAL OF CHROMATOGRAPHY, 1992, 596 (02): : 185 - 195
  • [34] SEPARATION OF INSECTICIDES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CABRAS, P
    MELONI, M
    PIRISI, FM
    JOURNAL OF CHROMATOGRAPHY, 1979, 176 (03): : 473 - 477
  • [35] SEPARATION OF NONAPEPTIDES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KRUMMEN, K
    FREI, RW
    JOURNAL OF CHROMATOGRAPHY, 1977, 132 (01): : 27 - 36
  • [36] LYMPHOKINE PURIFICATION BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    URDAL, DL
    MOCHIZUKI, D
    CONLON, PJ
    MARCH, CJ
    REMEROWSKI, ML
    EISENMAN, J
    RAMTHUN, C
    GILLIS, S
    JOURNAL OF CHROMATOGRAPHY, 1984, 296 (JUL): : 171 - 179
  • [37] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF METHYL ISOCYANATE
    RAGHUVEERAN, CD
    KAUSHIK, MP
    JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT): : 446 - 449
  • [38] DETERMINATION OF URANIUM BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CASOLI, A
    MANGIA, A
    PREDIERI, G
    ANALYTICAL CHEMISTRY, 1985, 57 (02) : 561 - 563
  • [39] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF CATECHOLAMINES AND THEIR CONGENERS
    ASMUS, PA
    FREED, CR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (SEP): : 40 - 40
  • [40] SILANOPHILIC INTERACTIONS IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BAYER, E
    PAULUS, A
    JOURNAL OF CHROMATOGRAPHY, 1987, 400 : 1 - 4