DESIGN AND THERMAL-STRESS ANALYSIS OF HIGH-POWER X-RAY MONOCHROMATORS COOLED WITH LIQUID-NITROGEN

被引:3
|
作者
ROGERS, CS
ASSOUFID, L
机构
[1] Argonne Natl Lab, Argonne, United States
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1995年 / 66卷 / 02期
关键词
Monochromators;
D O I
10.1063/1.1145705
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cryogenically cooled, single-crystal silicon, x-ray monochromators offer much better thermal performance than room-temperature silicon monochromators. The improved performance can be quantified by a figure-of-merit equal to the ratio of the thermal conductivity to the coefficient of thermal expansion. This ratio increases by about a factor of 50 as the temperature is decreased from 300 to 100 K. An extensive thermal and structural finite element analysis is presented for an inclined, liquid-nitrogen-cooled, Si monochromator crystal diffracting 4.2 keV photons from the [111] planes using undulator A at the Advanced Photon Source. The angular size of the beam accepted on the crystal was chosen to be 50 μrad vertically and 120 μrad horizontally. The deflection parameter, K, was 2.17 for all cases. The peak power density at normal incidence to the beam was calculated to be 139 W/mm2, and the total power was 750 W at a distance of 30 m from the source for a positron current of 100 mA. The crystal was oriented in the inclined geometry with an inclination angle of 85° for all cases. The performance of the crystal was investigated for beam currents of 100, 200, and 300 mA. The calculated peak slopes of the diffraction plane over the extent of the beam footprint were -1.17, -2.35, and 0.33 μrad, and the peak temperatures were 88.2, 102.6, and 121.4 K, respectively. The variation in the Bragg angle due to change in d spacing across the beam footprint was less than 1 μrad for all cases. These results indicate that a properly designed, cryogenically cooled, inclined silicon monochromator can deliver the full brilliance of undulator A at even the highest machine currents. © 1995 American Institute of Physics.
引用
收藏
页码:2200 / 2202
页数:3
相关论文
共 50 条
  • [1] PERFORMANCE ANALYSIS OF HIGH-POWER SYNCHROTRON X-RAY MONOCHROMATORS
    KHOUNSARY, AM
    CHRZAS, JJ
    MILLS, DM
    VICCARO, PJ
    OPTICAL ENGINEERING, 1990, 29 (10) : 1273 - 1280
  • [2] X-RAY MONOCHROMATORS FOR HIGH-POWER SYNCHROTRON RADIATION SOURCES
    HART, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2): : 306 - 311
  • [3] Modelling the power threshold and optimum thermal deformation of indirectly liquid-nitrogen cryo-cooled Si monochromators
    Khosroabadi, Hossein
    Alianelli, Lucia
    Sanchez-Navarro, Pablo
    Peach, Andrew
    Sawhney, Kawal
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 : 478 - 484
  • [4] Liquid nitrogen cooled X-ray monochromator for high total power loads
    Rowen, M
    Peck, JW
    Rabedeau, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 400 - 403
  • [5] Limitations of Liquid Nitrogen Cooling of High Heat Load X-Ray Monochromators
    Khounsary, Ali
    Strons, Philip
    Kujala, Naresh
    Macrander, Albert
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VII, 2012, 8502
  • [6] UNDULATOR HEAT LOADING STUDIES ON X-RAY MONOCHROMATORS COOLED WITH LIQUID GALLIUM
    BILDERBACK, DH
    HENDERSON, C
    WHITE, J
    SMITHER, RK
    FORSTER, GA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1973 - 1976
  • [7] THERMAL-STRESS ANALYSIS AND DIFFRACTION SIMULATION OF A STANDARD AND INCLINED GALLIUM-COOLED HIGH-HEAT-LOAD X-RAY MONOCHROMATOR
    ROGERS, CS
    MACRANDER, AT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (03): : 561 - 568
  • [8] POWER LOSSES OF LIQUID-NITROGEN COOLED HIGH-CURRENT CABLES
    HELLER, I
    CRYOGENICS, 1975, 15 (05) : 243 - 245
  • [9] HIGH-POWER OPERATION OF ACCELERATOR STRUCTURES AT LIQUID-NITROGEN TEMPERATURE
    MCEUEN, AH
    LUI, P
    TANABE, E
    VAGUINE, V
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 2972 - 2974
  • [10] A COMPACT HIGH-POWER X-RAY TUBE FOR FLUORESCENT X-RAY SPECTRAL ANALYSIS
    SOBOLEVS.GD
    IOFFE, YK
    NIKOLAEN.GM
    FRIDMAN, EM
    INDUSTRIAL LABORATORY, 1965, 31 (11): : 1766 - &