SYNTHESIS AND CHARACTERIZATION OF A POLYMERIC FLUOROCARBON-DIAMINE REVERSED-PHASE WEAK ANION-EXCHANGE SILICA HPLC COLUMN PACKING

被引:7
|
作者
DANIELSON, ND
WANGSA, J
SHAMSI, SA
机构
[1] Department of Chemistry, Miami University, Ohio
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1995年 / 18卷 / 13期
关键词
D O I
10.1080/10826079508009310
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polymeric fluorocarbon-diamine silica column packings were synthesized by first reacting a copolymer of chlorotrifluoroethylene and vinylidene fluoride (Kel-F 800) with piperazine and then reacting this product with aminopropyl silica. This mixed mode reversed phase-weak anion exchange HPLC column and a hydrocarbon (C-8) weak anion exchange silica HPLC column were compared for the separation of aromatic organic acids. Although the fluorocarbon column was generally less retentive than the hydrocarbon one, good resolution and fast analysis of simple mixtures was still possible. Nucleotides were retained longer on the fluorocarbon column. Good alkaline pH stability of the polymeric fluorocarbon-diamine silica column packing was exhibited.
引用
收藏
页码:2579 / 2592
页数:14
相关论文
共 50 条
  • [31] Poly(1-allylimidazole)-grafted silica, a new specific stationary phase for reversed-phase and anion-exchange liquid chromatography
    Sun, Min
    Qiu, Hongdeng
    Wang, Licheng
    Liu, Xia
    Jiang, Shengxiang
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) : 3904 - 3909
  • [32] COMPARISON OF REVERSED-PHASE AND WEAK ANION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR PEPTIDE SEPARATIONS
    DIZDAROGLU, M
    KRUTZSCH, HC
    JOURNAL OF CHROMATOGRAPHY, 1983, 264 (02): : 223 - 229
  • [33] Monolithic columns with mixed modes of reversed-phase and anion-exchange stationary phase for capillary electrochromatography
    Fu, HJ
    Xie, CH
    Xiao, H
    Dong, J
    Hu, JW
    Zou, HF
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) : 237 - 244
  • [34] Mixed-phase weak anion-exchange/reversed-phase LC-MS/MS for analysis of nucleotide sugars in human fibroblasts
    Rahm, Moritz
    Kwast, Hanneke
    Wessels, Hans J. C. T.
    Noga, Marek J.
    Lefeber, Dirk J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (15) : 3595 - 3604
  • [35] A new weak anion-exchange/reversed-phase mixed-mode stationary phase for simultaneous separation of basic, acidic and neutral pharmaceuticals
    Liu, Xiaodong
    Pohl, Christopher
    LC GC EUROPE, 2007, : 33 - 33
  • [36] Silica-based monolithic columns with mixed-mode reversed-phase/weak anion-exchange selectivity principle for high-performance liquid chromatography
    Nogueira, Raquel
    Lubda, Dieter
    Leitner, Alexander
    Bicker, Wolfgang
    Maier, Norbert M.
    Laemmerhofer, Michael
    Lindner, Wolfgang
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (07) : 966 - 978
  • [37] A highly stable alkyl-amide silica-based column packing for reversed-phase HPLC of polar and ionizable compounds
    Kirkland, JJ
    Henderson, JW
    Martosella, JD
    Bidlingmeyer, BA
    Vasta-Russell, J
    Adams, JB
    LC GC NORTH AMERICA, 1999, 17 (07): : 634 - 639
  • [38] SILICA-BASED AND POLYMERIC COLUMNS FOR REVERSED-PHASE HPLC ANALYSIS OF CHEDDAR CHEESE
    LICHAN, E
    KWAN, L
    NAKAI, S
    AMANTEA, GF
    JOURNAL OF FOOD SCIENCE, 1992, 57 (02) : 350 - 354
  • [39] Direct aqueous determination of glyphosate and related compounds by liquid chromatography/tandem mass spectrometry using reversed-phase and weak anion-exchange mixed-mode column
    Hao, Chunyan
    Morse, David
    Morra, Franca
    Zhao, Xiaoming
    Yang, Paul
    Nunn, Brian
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (33) : 5638 - 5643
  • [40] ANION-EXCHANGE CHROMATOGRAPHY ON SELECTED SILICA-BASED REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS
    SECREAST, SL
    JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2): : 99 - 111