SYNTHESIS AND CHARACTERIZATION OF A POLYMERIC FLUOROCARBON-DIAMINE REVERSED-PHASE WEAK ANION-EXCHANGE SILICA HPLC COLUMN PACKING

被引:7
|
作者
DANIELSON, ND
WANGSA, J
SHAMSI, SA
机构
[1] Department of Chemistry, Miami University, Ohio
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1995年 / 18卷 / 13期
关键词
D O I
10.1080/10826079508009310
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polymeric fluorocarbon-diamine silica column packings were synthesized by first reacting a copolymer of chlorotrifluoroethylene and vinylidene fluoride (Kel-F 800) with piperazine and then reacting this product with aminopropyl silica. This mixed mode reversed phase-weak anion exchange HPLC column and a hydrocarbon (C-8) weak anion exchange silica HPLC column were compared for the separation of aromatic organic acids. Although the fluorocarbon column was generally less retentive than the hydrocarbon one, good resolution and fast analysis of simple mixtures was still possible. Nucleotides were retained longer on the fluorocarbon column. Good alkaline pH stability of the polymeric fluorocarbon-diamine silica column packing was exhibited.
引用
收藏
页码:2579 / 2592
页数:14
相关论文
共 50 条
  • [21] Multi-modal applicability of a reversed-phase/weak-anion exchange material in reversed-phase, anion-exchange, ion-exclusion, hydrophilic interaction and hydrophobic interaction chromatography modes
    Michael Lämmerhofer
    Raquel Nogueira
    Wolfgang Lindner
    Analytical and Bioanalytical Chemistry, 2011, 400 : 2517 - 2530
  • [22] Multi-modal applicability of a reversed-phase/weak-anion exchange material in reversed-phase, anion-exchange, ion-exclusion, hydrophilic interaction and hydrophobic interaction chromatography modes
    Laemmerhofer, Michael
    Nogueira, Raquel
    Lindner, Wolfgang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (08) : 2517 - 2530
  • [23] Rapid analysis of bovine caseins by reversed phase and anion-exchange HPLC
    Mas, S
    Marchesseau, S
    Lagaude, A
    Cuq, JL
    MILCHWISSENSCHAFT-MILK SCIENCE INTERNATIONAL, 1999, 54 (11): : 606 - 610
  • [24] Open tubular columns with mixed-mode reversed-phase and weak anion-exchange stationary phase for capillary electrochromatography
    Lei, Jie
    Zhang, Xiangmin
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (12) : 1996 - 2002
  • [25] Characterization of a highly stable mixed-mode reversed-phase/weak anion-exchange stationary phase based on hybrid organic/inorganic particles
    Walter, Thomas H.
    Alden, Bonnie A.
    Field, Jessica A.
    Lawrence, Nicole L.
    Osterman, Donna L.
    Patel, Amit, V
    DeLoffi, Maureen A.
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (05) : 1005 - 1014
  • [26] Characterization of a highly stable mixed-mode reversed-phase/weak anion-exchange stationary phase based on hybrid organic/inorganic particles
    Waters Corporation, Milford
    MA, United States
    J. Sep. Sci., 1615, 5 (1005-1014):
  • [27] A Weak Cation-Exchange, Reversed-Phase Mixed-Mode HPLC Column and its Applications
    Liu, Xiaodong
    Pohl, Christopher
    AMERICAN LABORATORY, 2009, 41 (05) : 26 - +
  • [28] Comparison of reversed-phase, anion-exchange, and hydrophilic interaction HPLC for the analysis of nucleotides involved in biological enzymatic pathways
    Carr, Allison Fabino
    Patel, Darshan C.
    Lopez, Diego
    Armstrong, Daniel W.
    Ryzhov, Victor
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2019, 42 (7-8) : 184 - 193
  • [29] High-Performance Liquid Chromatographic Determination of Inorganic Anions by Using a Reversed-Phase Column as an Anion-Exchange Stationary Phase
    Miyashita, Masahiro
    Seyama, Yoshiyuki
    Obata, Toshio
    BUNSEKI KAGAKU, 2011, 60 (10) : 799 - 805
  • [30] DETERMINATION OF FOLIC-ACID IN COMMERCIAL DIETS BY ANION-EXCHANGE SOLID-PHASE EXTRACTION AND SUBSEQUENT REVERSED-PHASE HPLC
    SCHIEFFER, GW
    WHEELER, GP
    CIMINO, CO
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (13): : 2659 - 2669