REDUCTION OF RF PENETRATION EFFECTS IN HIGH-FIELD IMAGING

被引:59
作者
FOO, TKF
HAYES, CE
KANG, YW
机构
[1] UNIV WISCONSIN,DEPT MED PHYS,MADISON,WI 53706
[2] GE ASTRO SPACE DIV,PRINCETON,NJ 08540
关键词
D O I
10.1002/mrm.1910230209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method of correcting for the RF inhomogeneity in the body by dielectric loading of the coil‐to‐shield space in an RF resonator (coil and shield assembly) is described. The presence of the RF coil and RF shield have significant effects on RF homogeneity. Based on theoretical calculations, a method for adjusting the RF homogeneity by manipulating the axial propagation constant, kz, is proposed. This is accomplished by loading the coil‐to‐shield space with dielectric material of suitable relative permittivity so as to increase kz and decrease the radial propagation constant, kp. In this manner, the radial wavelength (λp, = 2π/kp) can be increased relative to the body dimensions, and the field amplitude variations in the axial plane minimized. Theoretical calculations indicate that a value of between 30 and 40 for the relative permittivity of the dielectric material in the coil‐to‐shield space would reduce the RF field inhomogeneity from ±15% to about ±3% over a central 30‐cm‐diameter region of a homogeneous 40‐cm‐diameter body at both 64 and 170 MHz. The theoretical model was verified in laboratory measurements of the |B1|, field generated in a test coil at 170 MHz which was scaled to correspond to a body at 64 MHz. However, the improved RF field homogeneity would be accompanied by increased RF power requirements and reduced coil sensitivity. © 1992 Academic Press, Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:287 / 301
页数:15
相关论文
共 18 条
  • [1] RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING
    BOTTOMLEY, PA
    ANDREW, ER
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) : 630 - 643
  • [2] TECHNIQUE FOR MEASUREMENT OF TISSUE IMPEDANCE FROM 1 TO 100 MHZ USING A VECTOR IMPEDANCE METER
    BOTTOMLEY, PA
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1978, 11 (05): : 413 - 414
  • [3] A LAYER MODEL FOR RF PENETRATION, HEATING, AND SCREENING IN NMR
    BROWN, RW
    HAACKE, EM
    MARTENS, MA
    PATRICK, JL
    ZYPMAN, FR
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 80 (02): : 225 - 247
  • [4] RADIOFREQUENCY FIELD PROPAGATION IN CONDUCTIVE NMR SAMPLES
    CARLSON, JW
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03): : 563 - 573
  • [5] THE FIELD-DEPENDENCE OF NMR IMAGING .1. LABORATORY ASSESSMENT OF SIGNAL-TO-NOISE RATIO AND POWER DEPOSITION
    CHEN, CN
    SANK, VJ
    COHEN, SM
    HOULT, DI
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) : 722 - 729
  • [6] EDELSTEIN WA, 1987, Patent No. 4680548
  • [7] AN ANALYTICAL MODEL FOR THE DESIGN OF RF RESONATORS FOR MR BODY IMAGING
    FOO, TKF
    HAYES, CE
    KANG, YW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (02) : 165 - 177
  • [8] FOO TKF, 1989, 8TH ANN M, P993
  • [9] COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING
    GLOVER, GH
    HAYES, CE
    PELC, NJ
    EDELSTEIN, WA
    MUELLER, OM
    HART, HR
    HARDY, CJ
    ODONNELL, M
    BARBER, WD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) : 255 - 270
  • [10] Hayes C, 1987, U.S. Patent, Patent No. [# 4,694,255, 4694255, US patent 4,694,255. 1987]