Flexible Stabilisation of the Degenerative Lumbar Spine Using PEEK Rods

被引:13
作者
Benezech, Jacques [1 ]
Garlenq, Bruno [2 ]
Larroque, Gilles [3 ]
机构
[1] Clin Millenaire, Serv Neurochirurg, F-34000 Montpellier, France
[2] Ctr Hosp Paul Coste Floret, Serv Reeducat Fonctionnelle, F-34240 Lamalou Les Bains, France
[3] Invibio Ltd, Ctr Technol, Hillhouse Int, Thornton Cleveleys FY5 4QD, Lancs, England
关键词
D O I
10.1155/2016/7369409
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Posterior lumbar interbody fusion using cages, titanium rods, and pedicle screws is considered today as the gold standard of surgical treatment of lumbar degenerative disease and has produced satisfying long-term fusion rates. However this rigid material could change the physiological distribution of load at the instrumental and adjacent segments, a main cause of implant failure and adjacent segment disease, responsible for a high rate of further surgery in the following years. More recently, semirigid instrumentation systems using rods made of polyetheretherketone (PEEK) have been introduced. This clinical study of 21 patients focuses on the clinical and radiological outcomes of patients with lumbar degenerative disease treated with Initial VEOS PEEKY-Optima system (Innov'Spine, France) composed of rods made from PEEK-OPTIMAY polymer (Invibio Biomaterial Solutions, UK) without arthrodesis. With an average follow-up of 2 years and half, the chances of reoperation were significantly reduced (4.8%), quality of life was improved (ODI = 16%), and the adjacent disc was preserved in more than 70% of cases. Based on these results, combined with the biomechanical and clinical data already published, PEEK rods systems can be considered as a safe and effective alternative solution to rigid ones.
引用
收藏
页数:7
相关论文
共 52 条
[41]   Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation [J].
Ponnappan, Ravi K. ;
Serhan, Hassan ;
Zarda, Brett ;
Patel, Ravi ;
Albert, Todd ;
Vaccaro, Alexander R. .
SPINE JOURNAL, 2009, 9 (03) :263-267
[42]   Comparative effectiveness of PEEK rods versus titanium alloy rods in lumbar fusion: A preliminary report [J].
Qi, Lei ;
Li, Mu ;
Zhang, Shuai ;
Xue, Jingsong ;
Si, Haipeng .
ACTA NEUROCHIRURGICA, 2013, 155 (07) :1187-1193
[43]  
Rahm MD, 1996, J SPINAL DISORD, V9, P392
[44]   The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titanium [J].
Sagomonyants, Karen B. ;
Jarman-Smith, Marcus L. ;
Devine, John N. ;
Aronow, Michael S. ;
Gronowicz, Gloria A. .
BIOMATERIALS, 2008, 29 (11) :1563-1572
[45]   Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis [J].
Schnake, KJ ;
Schaeren, S ;
Jeanneret, B .
SPINE, 2006, 31 (04) :442-449
[46]   EFFECTS OF SPINAL INSTRUMENTATION ON FUSION OF THE LUMBOSACRAL SPINE [J].
SCHWAB, FJ ;
NAZARIAN, DG ;
MAHMUD, F ;
MICHELSEN, CB .
SPINE, 1995, 20 (18) :2023-2028
[47]   Mechanical supplementation by non-rigid fixation in degenerative intervertebral lumbar segments:: the Wallis system [J].
Sénégas, J .
EUROPEAN SPINE JOURNAL, 2002, 11 (Suppl 2) :S164-S169
[48]   Dynamic stabilization devices in the treatment of low back pain [J].
Sengupta, DK .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2004, 35 (01) :43-+
[49]   The Mechanical Effect of Commercially Pure Titanium and Polyetheretherketone Rods on Spinal Implants at the Operative and Adjacent Levels [J].
Turner, Joseph L. ;
Paller, David J. ;
Murrell, Charles B. .
SPINE, 2010, 35 (21) :E1076-E1082
[50]   Effect of lumbar interbody cage geometry on construct stability: A cadaveric study [J].
Vadapalli, Sasidhar ;
Robon, Matt ;
Biyani, Ashok ;
Sairyo, Koichi ;
Khandha, Ashutosh ;
Goel, Vijay K. .
SPINE, 2006, 31 (19) :2189-2194