QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW USING N-13 AMMONIA AND REORIENTED DYNAMIC POSITRON EMISSION TOMOGRAPHIC IMAGING

被引:219
作者
KUHLE, WG
PORENTA, G
HUANG, SC
BUXTON, D
GAMBHIR, SS
HANSEN, H
PHELPS, ME
SCHELBERT, HR
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DEPT RADIOL SCI,DIV NUCL MED & BIOPHYS,LOS ANGELES,CA 90024
[2] UNIV CALIF LOS ANGELES,NUCL MED LAB,LOS ANGELES,CA 90024
[3] UNIV CALIF LOS ANGELES,BIOMED & ENVIRONM SCI LAB,LOS ANGELES,CA 90024
关键词
TOMOGRAPHY; POSITRON EMISSION; FLOW; MYOCARDIAL BLOOD;
D O I
10.1161/01.CIR.86.3.1004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Regional myocardial blood flow has been quantified using transaxial positron emission tomographic (PET) imaging and tracer kinetic modeling. However, the use of transaxial images limits the accuracy of regional partial volume corrections and the localization of the quantified regional flow values. The purpose of the present study was to overcome both problems by calculating regional flows from reoriented short-axis PET images. Methods and Results. Twelve experiments were performed in four dogs. N-13-ammonia was injected intravenously while microspheres were administered into the left atrium during baseline, hyperemic, and low-flow conditions. Serial transaxial frames were acquired with a 15-plane PET scanner and reoriented into short-axis frames. The arterial input function and eight regional myocardial tissue activity curves were derived from the reoriented frames. The arterial input functions were corrected for ammonia metabolites, and the myocardial tissue curves were corrected for spillover of activity, partial volume effects, and heterogeneities in the image's spatial resolution introduced during reorientation. Corrections for regional partial volume were based on estimates of the regional myocardial activity thickness derived from reoriented diastolic images of the heart. The myocardial N-13-ammonia kinetics were described with a two-pool compartmental model. Values of regional myocardial blood flow by PET correlated linearly with those by microspheres (slope, 0.94; y intercept, 0.06 ml/min/g; r=0.93) over a wide range of flows. Conclusions. Regional myocardial blood flow can be measured accurately and noninvasively from serially acquired and reoriented short-axis N-13-ammonia images, thus overcoming limitations inherent to the use of transaxially acquired images and permitting a more complete evaluation of regional blood flows throughout the left ventricular myocardium.
引用
收藏
页码:1004 / 1017
页数:14
相关论文
共 22 条
  • [1] NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW IN CORONARY-ARTERY DISEASE WITH OXYGEN-15-LABELED CARBON-DIOXIDE INHALATION AND POSITRON EMISSION TOMOGRAPHY
    ARAUJO, LI
    LAMMERTSMA, AA
    RHODES, CG
    MCFALLS, EO
    IIDA, H
    RECHAVIA, E
    GALASSI, A
    DESILVA, R
    JONES, T
    MASERI, A
    [J]. CIRCULATION, 1991, 83 (03) : 875 - 885
  • [2] VALIDITY OF MICROSPHERE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS
    BASSINGTHWAIGHTE, JB
    MALONE, MA
    MOFFETT, TC
    KING, RB
    LITTLE, SE
    LINK, JM
    KROHN, KA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (01): : H184 - H193
  • [3] NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY
    BERGMANN, SR
    HERRERO, P
    MARKHAM, J
    WEINHEIMER, CJ
    WALSH, MN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) : 639 - 652
  • [4] CHOI Y, 1991, Journal of Nuclear Medicine, V32, P926
  • [5] HENZE E, 1983, J NUCL MED, V24, P987
  • [6] MEASUREMENT OF MYOCARDIAL BLOOD-FLOW WITH POSITRON EMISSION TOMOGRAPHY - CORRECTION FOR COUNT SPILLOVER AND PARTIAL VOLUME EFFECTS
    HERRERO, P
    MARKHAM, J
    MYEARS, DW
    WEINHEIMER, CJ
    BERGMANN, SR
    [J]. MATHEMATICAL AND COMPUTER MODELLING, 1988, 11 : 807 - 812
  • [7] BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES
    HEYMANN, MA
    PAYNE, BD
    HOFFMAN, JIE
    RUDOLPH, AM
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) : 55 - 79
  • [8] QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE
    HOFFMAN, EJ
    HUANG, SC
    PHELPS, ME
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) : 299 - 308
  • [9] NONINVASIVE QUANTIFICATION OF REGIONAL BLOOD-FLOW IN THE HUMAN HEART USING N-13 AMMONIA AND DYNAMIC POSITRON EMISSION TOMOGRAPHIC IMAGING
    HUTCHINS, GD
    SCHWAIGER, M
    ROSENSPIRE, KC
    KRIVOKAPICH, J
    SCHELBERT, H
    KUHL, DE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (05) : 1032 - 1042
  • [10] STABILITY OF HETEROGENEITY OF MYOCARDIAL BLOOD-FLOW IN NORMAL AWAKE BABOONS
    KING, RB
    BASSINGTHWAIGHTE, JB
    HALES, JRS
    ROWELL, LB
    [J]. CIRCULATION RESEARCH, 1985, 57 (02) : 285 - 295