MICROTITER ENZYME-LINKED-IMMUNOSORBENT-ASSAY USING RECOMBINANT-DERIVED ANTIGENS VERSUS WESTERN-BLOT IN THE CONFIRMATION OF PRESENCE OF ANTIBODIES AGAINST THE HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1

被引:1
作者
ROOSENDAAL, R
VANKAMP, GJ
MULDER, C
CALLIAUW, J
KEMPERS, J
DIRKS, M
WOLTERS, EC
TENKATE, RW
机构
[1] FREE UNIV AMSTERDAM,DEPT CLIN CHEM,1007 MC AMSTERDAM,NETHERLANDS
[2] FREE UNIV AMSTERDAM,DEPT NEUROL,1007 MC AMSTERDAM,NETHERLANDS
[3] ELISABETH HOSP,DEPT INTERNAL MED,HAARLEM,NETHERLANDS
关键词
HIV-1; ANTIBODY-CONFIRMATION; MICROTITER ELISA;
D O I
10.1016/0166-0934(93)90062-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microtiter enzyme-linked immunosorbent assay using recombinant derived antigens was compared with the Western blot (Dupont) in the confirmation of the presence of antibodies against the human immunodeficiency virus type 1 (HIV-1). Of 104 sera (104 individuals) that were negative by a screening ELISA, 91 were also negative by both confirmation assays. In three sera only the microtiter assay was found to be indeterminate, and in nine other sera only Western blot. The only microtiter assay positive serum was from a male patient at risk for infection with HIV. 279 sera from 83 patients were found positive by screening. Of these, 223 sera were positive in both confirmation assays, and no serum was negative. Only one serum was indeterminate by the microtiter ELISA in contrast to 55 sera, including follow-up samples from 25 patients, most of whom had AIDS, by Western blot (Dupont criteria). However, the number of Western blot indeterminate sera decreased substantially applying less stringent criteria for interpretation. In conclusion, the microtiter ELISA performed well as a confirmation test for the presence of antibodies against HIV-1. In addition, the results demonstrate that in the microtiter assay the envelope peptide kp41 is highly discriminative in detecting anti-HIV-1 negative and anti-HIV-1 positive sera.
引用
收藏
页码:271 / 280
页数:10
相关论文
共 13 条
[1]   DIAGNOSIS OF HUMAN IMMUNODEFICIENCY VIRUS-INFECTION BY IMMUNOASSAY USING A MOLECULARLY CLONED AND EXPRESSED VIRUS ENVELOPE POLYPEPTIDE - COMPARISON TO WESTERN-BLOT ON 2707 CONSECUTIVE SERUM SAMPLES [J].
BURKE, DS ;
BRANDT, BL ;
REDFIELD, RR ;
LEE, TH ;
THORN, RM ;
BELTZ, GA ;
HUNG, CH .
ANNALS OF INTERNAL MEDICINE, 1987, 106 (05) :671-676
[2]  
CHIANG CS, 1989, CLIN CHEM, V35, P946
[3]  
COOPER DA, 1985, LANCET, V1, P537
[4]   RELIABLE DETECTION OF INDIVIDUALS SEROPOSITIVE FOR THE HUMAN IMMUNODEFICIENCY VIRUS (HIV) BY COMPETITIVE IMMUNOASSAYS USING ESCHERICHIA-COLI-EXPRESSED HIV STRUCTURAL PROTEINS [J].
DAWSON, GJ ;
HELLER, JS ;
WOOD, CA ;
GUTIERREZ, RA ;
WEBBER, JS ;
HUNT, JC ;
HOJVAT, SA ;
SENN, D ;
DEVARE, SG ;
DECKER, RH .
JOURNAL OF INFECTIOUS DISEASES, 1988, 157 (01) :149-155
[5]   HUMAN IMMUNODEFICIENCY VIRUS PROTEASE EXPRESSED IN ESCHERICHIA-COLI EXHIBITS AUTOPROCESSING AND SPECIFIC MATURATION OF THE GAG PRECURSOR [J].
DEBOUCK, C ;
GORNIAK, JG ;
STRICKLER, JE ;
MEEK, TD ;
METCALF, BW ;
ROSENBERG, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1987, 84 (24) :8903-8906
[6]   COMPARISON OF DETECTION OF ANTIBODY TO THE ACQUIRED-IMMUNE-DEFICIENCY-SYNDROME VIRUS BY ENZYME-IMMUNOASSAY, IMMUNOFLUORESCENCE, AND WESTERN-BLOT METHODS [J].
GALLO, D ;
DIGGS, JL ;
SHELL, GR ;
DAILEY, PJ ;
HOFFMAN, MN ;
RIGGS, JL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 23 (06) :1049-1051
[7]   COMPARISON OF WESTERN BLOT (IMMUNOBLOT) BASED ON RECOMBINANT-DERIVED P41 WITH CONVENTIONAL TESTS FOR SERODIAGNOSIS OF HUMAN IMMUNODEFICIENCY VIRUS-INFECTIONS [J].
HOFBAUER, JM ;
SCHULZ, TF ;
HENGSTER, P ;
LARCHER, C ;
ZANGERLE, R ;
KOFLER, H ;
FRITSCH, P ;
WACHTER, H ;
DIERICH, MP .
JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (01) :116-120
[8]   RELIABLE CONFIRMATION OF ANTIBODIES TO HUMAN IMMUNODEFICIENCY VIRUS TYPE-1 (HIV-1) WITH AN ENZYME-LINKED IMMUNOASSAY USING RECOMBINANT ANTIGENS DERIVED FROM THE HIV-1 GAG, POL, AND ENV GENES [J].
NG, VL ;
CHIANG, CS ;
DEBOUCK, C ;
MCGRATH, MS ;
GROVE, TH ;
MILLS, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (05) :977-982
[9]   DETECTION OF EARLY ANTIBODIES IN HUMAN IMMUNODEFICIENCY VIRUS-INFECTION BY ENZYME-LINKED-IMMUNOSORBENT-ASSAY, WESTERN-BLOT, AND RADIOIMMUNOPRECIPITATION [J].
SAAH, AJ ;
FARZADEGAN, H ;
FOX, R ;
NISHANIAN, P ;
RINALDO, CR ;
PHAIR, JP ;
FAHEY, JL ;
LEE, TH ;
POLK, BF .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (09) :1605-1610
[10]   ENZYME-IMMUNOASSAY USING A NOVEL RECOMBINANT POLYPEPTIDE TO DETECT HUMAN-IMMUNODEFICIENCY-VIRUS ENV ANTIBODY [J].
THORN, RM ;
BELTZ, GA ;
HUNG, CH ;
FALLIS, BF ;
WINKLE, S ;
CHENG, KL ;
MARCIANI, DJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (07) :1207-1212