APPROACHES TO OPTIMIZATION OF PRECISION IN CAPILLARY ELECTROPHORESIS

被引:117
作者
ALTRIA, KD [1 ]
FABRE, H [1 ]
机构
[1] FAC PHARM MONTPELLIER, CHIM ANALYT LAB, F-34060 MONTPELLIER 1, FRANCE
关键词
CAPILLARY ELECTROPHORESIS; REPEATABILITY; PRECISION OPTIMIZATION;
D O I
10.1007/BF02290363
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A study has been performed to obtain insight into the relative importance of critical factors affecting the repeatability of hydrodynamic injections in CE. Precision was measured for repeated analysis of a test mixture containing two acidic compounds. The use of an internal standard was clearly shown to improve precision especially when peak area precision was poor. It is suggested that precision is maximised by employing a combination of a constant temperature, an appropriate electrolyte system, an internal standard, long injection times, and high sample concentrations. Other factors are discussed, but are classified as having only a minor impact.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 23 条
  • [1] SENSITIVITY ENHANCEMENT FOR CAPILLARY ELECTROPHORESIS
    ALBIN, M
    GROSSMAN, PD
    MORING, SE
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (10) : A489 - A497
  • [2] AN INTER-COMPANY CROSS-VALIDATION EXERCISE ON CAPILLARY ELECTROPHORESIS TESTING OF DOSE UNIFORMITY OF PARACETAMOL CONTENT IN FORMULATIONS
    ALTRIA, KD
    CLAYTON, NG
    HART, M
    HARDEN, RC
    HEVIZI, J
    MAKWANA, JV
    PORTSMOUTH, MJ
    [J]. CHROMATOGRAPHIA, 1994, 39 (3-4) : 180 - 184
  • [3] ESSENTIAL PEAK AREA NORMALIZATION FOR QUANTITATIVE IMPURITY CONTENT DETERMINATION BY CAPILLARY ELECTROPHORESIS
    ALTRIA, KD
    [J]. CHROMATOGRAPHIA, 1993, 35 (3-4) : 177 - 182
  • [4] USE OF CAPILLARY ELECTROPHORESIS FOR THE DETERMINATION OF VITAMINS OF THE B-GROUP IN PHARMACEUTICAL PREPARATIONS
    BOONKERD, S
    DETAEVERNIER, MR
    MICHOTTE, Y
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 670 (1-2) : 209 - 214
  • [5] THE REPEATABILITY OF THE QUANTITATIVE-ANALYSIS IN ELECTROCHROMATOGRAPHY
    COUFAL, P
    CLAESSENS, HA
    CRAMERS, CA
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (17): : 3623 - 3652
  • [6] COUFAL P, 1993, HRC J HIGH RES CHROM, V17, P325
  • [7] PROBLEMS OF QUANTITATIVE INJECTION IN CAPILLARY ZONE ELECTROPHORESIS
    DOSE, EV
    GUIOCHON, G
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (02) : 123 - 128
  • [8] INTERNAL STANDARDIZATION TECHNIQUE FOR CAPILLARY ZONE ELECTROPHORESIS
    DOSE, EV
    GUIOCHON, GA
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (11) : 1154 - 1158
  • [9] EWING A G, 1989, Analytical Chemistry, V61, P292
  • [10] SPONTANEOUS INJECTION IN MICROCOLUMN SEPARATIONS
    FISHMAN, HA
    AMUDI, NM
    LEE, TT
    SCHELLER, RH
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (14) : 2318 - 2329