PHOTOINDUCED REDUCTION OF NITRATE TO NITRITE AND ITS APPLICATION TO THE SENSITIVE DETERMINATION OF NITRATE IN NATURAL-WATERS

被引:52
作者
MOTOMIZU, S
SANADA, M
机构
[1] Department of Chemistry, Faculty of Science, Okayama University, Okayama-shi, 700, Tsushimanaka
关键词
FLOW INJECTION; NITRATE; NITRITE; PHOTOINDUCED REDUCTION; ACTIVATOR;
D O I
10.1016/0003-2670(94)00334-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and less poisonous flow-injection method for the determination of nitrate using a newly developed activator for the reduction of nitrate to nitrite is presented. Nitrate in sample solutions injected in a buffered carrier containing the activator is first reduced to nitrite while flowing in a reduction coil installed in a photo-reactor; then nitrite is determined spectrophotometrically on the basis of a diazotization-coupling reaction. The photo-reactor is made of a low-pressure mercury lamp, a poly(tetrafluoroethylene) (PTFE) tubing and a reflection covering. The PTFE tubing is wound directly around the mercury lamp, and it is wrapped up in aluminium foil. By using the photo-reactor and EDTA analogues as an activator in carrier, the reduction efficiency reaches about 70-84%. In a simple flow system for nitrate determination, the manifold with double streams is adopted. The carrier stream, in which the sample solution is injected, is a buffered solution (pH 7.0) containing phosphate and EDTA analogues, and the reagent solution contains chromogenic reagents. In a now system for simultaneous determination of nitrite and nitrate, the carrier stream is bifurcated after a sample injection valve. The detection limits for nitrate and nitrite are about 3 x 10(-8) M, and the sample throughput is about 30 samples per h for nitrate determination, and is about 10 samples per h for the simultaneous determination of nitrate and nitrite.
引用
收藏
页码:406 / 412
页数:7
相关论文
共 19 条
  • [11] DETERMINATION OF NITRATE IN NATURAL-WATERS BY FLOW-INJECTION ANALYSIS
    NAKASHIMA, S
    YAGI, M
    ZENKI, M
    TAKAHASHI, A
    TOEI, K
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 319 (05): : 506 - 509
  • [12] NAKASHIMA S, 1982, BUNSEKI KAGAKU, V31, P732
  • [13] SIMULTANEOUS DETERMINATION OF IRON(II), IRON(III), AND TITANIUM(IV) BY FLOW-INJECTION ANALYSIS USING KINETIC SPECTROPHOTOMETRY WITH TIRON
    OGUMA, K
    KOZUKA, S
    KITADA, K
    KURODA, R
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 341 (09): : 545 - 549
  • [14] RUI SC, 1987, BUNSEKI KAGAKU, V36, P207
  • [15] RUIZ TP, 1992, ANALYST, V117, P1771
  • [16] FLOW-INJECTION ANALYSIS, PRINCIPLES, APPLICATIONS AND TRENDS
    RUZICKA, J
    HANSEN, EH
    [J]. ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) : 19 - 44
  • [17] DETERMINATION OF NITRATE IN NATURAL-WATERS WITH THE PHOTOINDUCED CONVERSION OF NITRATE TO NITRITE
    TAKEDA, K
    FUJIWARA, K
    [J]. ANALYTICA CHIMICA ACTA, 1993, 276 (01) : 25 - 32
  • [19] FLASH-PHOTOLYSIS OF NITRATE IONS IN AQUEOUS-SOLUTION
    WAGNER, I
    STREHLOW, H
    BUSSE, G
    [J]. ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-WIESBADEN, 1980, 123 (01): : 1 - 33