PHOTOINDUCED REDUCTION OF NITRATE TO NITRITE AND ITS APPLICATION TO THE SENSITIVE DETERMINATION OF NITRATE IN NATURAL-WATERS

被引:52
作者
MOTOMIZU, S
SANADA, M
机构
[1] Department of Chemistry, Faculty of Science, Okayama University, Okayama-shi, 700, Tsushimanaka
关键词
FLOW INJECTION; NITRATE; NITRITE; PHOTOINDUCED REDUCTION; ACTIVATOR;
D O I
10.1016/0003-2670(94)00334-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and less poisonous flow-injection method for the determination of nitrate using a newly developed activator for the reduction of nitrate to nitrite is presented. Nitrate in sample solutions injected in a buffered carrier containing the activator is first reduced to nitrite while flowing in a reduction coil installed in a photo-reactor; then nitrite is determined spectrophotometrically on the basis of a diazotization-coupling reaction. The photo-reactor is made of a low-pressure mercury lamp, a poly(tetrafluoroethylene) (PTFE) tubing and a reflection covering. The PTFE tubing is wound directly around the mercury lamp, and it is wrapped up in aluminium foil. By using the photo-reactor and EDTA analogues as an activator in carrier, the reduction efficiency reaches about 70-84%. In a simple flow system for nitrate determination, the manifold with double streams is adopted. The carrier stream, in which the sample solution is injected, is a buffered solution (pH 7.0) containing phosphate and EDTA analogues, and the reagent solution contains chromogenic reagents. In a now system for simultaneous determination of nitrite and nitrate, the carrier stream is bifurcated after a sample injection valve. The detection limits for nitrate and nitrite are about 3 x 10(-8) M, and the sample throughput is about 30 samples per h for nitrate determination, and is about 10 samples per h for the simultaneous determination of nitrate and nitrite.
引用
收藏
页码:406 / 412
页数:7
相关论文
共 19 条