STUDIES OF FLUID TRANSPORT IN POROUS ROCKS BY ECHO-PLANAR MRI

被引:23
|
作者
MANSFIELD, P
ISSA, B
机构
[1] Magnetic Resonance Centre, Department of Physics, University of Nottingham
关键词
FLUID TRANSPORT; EPI; POROUS ROCKS;
D O I
10.1016/0730-725X(94)91535-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Attempts to quantify the permeability constant that appears in Darcy's equation in terms of the porosity, tortuosity and surface area have been made by Kozeny and Carman. These results in turn have been translated by Seevers into expressions involving spin-lattice relaxation times. When this work was done originally in the mid-1960s, NMR imaging and spatially localised T-1 maps had not been invented. Therefore, bulk T-1 average values were used and it is not surprising to see substantial deviations from predicted permeabilities in bore core material. In this paper we re-examine the Kozeny-Carman and Seevers theories in the light of new techniques development for the localised measurement of both T-1 maps and fluid velocity maps. New results show spatially correlated T-1 and flow maps obtained from Bentheimer sandstone samples. These are discussed in terms of a localised permeability constant. By this means we show that the relationship between T-1 and permeability does not hold at the local level for isolated pixels within a larger specimen.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 50 条
  • [31] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [32] A novel object-independent "balanced" reference scan for echo-planar imaging
    Reeder, SB
    Faranesh, AZ
    Atalar, E
    McVeigh, ER
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (06): : 847 - 852
  • [33] 'Snap-shot' velocity vector mapping using echo-planar imaging
    Tayler, Alexander B.
    Sederman, Andrew J.
    Newling, Benedict
    Mantle, Mick D.
    Gladden, Lynn F.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 204 (02) : 266 - 272
  • [34] ADEPT: Accurate Diffusion Echo-Planar imaging with multi-contrast shoTs
    Shafieizargar, Banafshe
    Jeurissen, Ben
    Poot, Dirk H. J.
    Klein, Stefan
    Van Audekerke, Johan
    Verhoye, Marleen
    den Dekker, Arnold J.
    Sijbers, Jan
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 396 - 410
  • [35] Correction for distortion of echo-planar images used to calculate the apparent diffusion coefficient
    Haselgrove, JC
    Moore, JR
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) : 960 - 964
  • [36] Correction of shear artifact caused by unbalanced alternating readout gradient in echo-planar Imaging
    Chiou, JY
    Ahn, CB
    Muftuler, LT
    Nalcioglu, O
    PHYSICA MEDICA, 2003, 19 (02) : 175 - 179
  • [37] Readout-Segmented Echo-Planar DWI for the Detection of Cholesteatomas: Correlation with Surgical Validation
    Fischer, N.
    Schartinger, V. H.
    Dejaco, D.
    Schmutzhard, J.
    Riechelmann, H.
    Plaikner, M.
    Henninger, B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (06) : 1055 - 1059
  • [38] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [39] Comparison of the Image Quality of Turbo Spin Echo and Echo-Planar Diffusion-Weighted Imaging of the Head and Neck Region
    Sam, Ajina
    Misbah, Iffath
    Ram, Jasvant
    Raja, Sam
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [40] Fast 3D radiofrequency field mapping using echo-planar imaging
    Jiru, F.
    Klose, U.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1375 - 1379