INTRACORONARY AIR-FILLED ALBUMIN MICROSPHERES FOR MYOCARDIAL BLOOD-FLOW MEASUREMENT

被引:12
作者
ROVAI, D [1 ]
GHELARDINI, G [1 ]
TRIVELLA, MG [1 ]
BJORKLUND, G [1 ]
NEVOLA, E [1 ]
TADDEI, L [1 ]
DISTANTE, A [1 ]
LABBATE, A [1 ]
机构
[1] UNIV PISA,PISA,ITALY
关键词
D O I
10.1016/0735-1097(93)90792-Y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The aim of this study was to explore the possibility of quantifying coronary blood Bow by myocardial contrast echocardiography with air-filled serum albumin microspheres (Albunex). Background. Air-filled albumin microspheres have been proposed as an intravascular tracer for the study of myocardial perfusion by contrast echocardiography. Methods. In six anesthetized open chest dogs, the left circumflex coronary artery was cannulated and perfused by a roller pump with blood from the femoral artery. Both air-filled albumin microspheres (0.4 mi, 2 x 10(8) spheres/ml) and technetium-99m-labeled albumin were injected as a bolus into the coronary cannula at baseline and after treatment with dipyridamole (0.56 mg/kg body weight intravenously for 4 min). Two-dimensional echographic images of the left ventricular short axis were digitized to generate myocardial time-intensity curves; myocardial radioactivity was measured by an external detector to generate radionuclide time-activity curves. Results. After dipyridamole, left circumflex coronary artery blood Bow (as measured by both the pump and an electromagnetic Bow meter) significantly increased (from 1.06 +/- 0.28 to 3.61 +/- 1.43 ml/min per g of myocardium). Peak intensity and rise time of contrast echo curves were able to differentiate baseline myocardial perfusion from coronary hyperemia but did not show any significant correlation with coronary blood Bow. A weak inverse correlation with coronary blood Bow was provided by myocardial mean transit time of air-filled albumin microspheres (r = 0.33). Conversely, a close inverse correlation with coronary blood how was obtained by myocardial mean transit time of technetium-99m-labeled albumin (r = 0.95). Myocardial transit time of air-filled albumin microspheres (1.95 +/- 0.60 s) was also markedly shorter than that of labeled albumin (5.35 +/- 3.43 s, p < 0.001) and the measurements were less reproducible. Conclusions. In this experimental study, coronary blood how was not adequately quantified by myocardial contrast echocardiography with intracoronary injection of air filled albumin microspheres.
引用
收藏
页码:2014 / 2021
页数:8
相关论文
共 29 条
[1]   ASSESSMENT OF LOCATION AND SIZE OF MYOCARDIAL-INFARCTION WITH CONTRAST-ENHANCED ECHOCARDIOGRAPHY [J].
ARMSTRONG, WF ;
WEST, SR ;
MUELLER, TM ;
DILLON, JC ;
FEIGENBAUM, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (01) :63-69
[2]   MICROVESSEL MEAN TRANSIT-TIME AND BLOOD-FLOW VELOCITY OF SULFHEMOGLOBIN-RBC [J].
BAKER, CH ;
SUTTON, ET ;
DAVIS, DL .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (05) :H745-H749
[3]  
BAKER CH, 1964, J PHYSL, V206, P1291
[4]  
BIANCHI R, 1960, MINERVA MED, P295
[5]   ASSESSMENT OF MYOCARDIAL PERFUSION IN HUMANS BY CONTRAST ECHOCARDIOGRAPHY .1. EVALUATION OF REGIONAL CORONARY RESERVE BY PEAK CONTRAST INTENSITY [J].
CHEIRIF, J ;
ZOGHBI, WA ;
RAIZNER, AE ;
MINOR, ST ;
WINTERS, WL ;
KLEIN, MS ;
DEBAUCHE, TL ;
LEWIS, JM ;
ROBERTS, R ;
QUINONES, MA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (04) :735-743
[6]  
EDWARDS N, 1990, CIRCULATION S3, V82, P96
[7]   INTRAOPERATIVE CARDIOPLEGIC CONTRAST ECHOCARDIOGRAPHY FOR ASSESSING MYOCARDIAL PERFUSION DURING OPEN-HEART SURGERY [J].
GOLDMAN, ME ;
MINDICH, BP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (05) :1029-1034
[8]   CONTRAST ECHOCARDIOGRAPHIC MAPPING OF COLLATERALIZED MYOCARDIUM IN HUMANS BEFORE AND AFTER CORONARY ANGIOPLASTY [J].
GRILL, HP ;
BRINKER, JA ;
TAUBE, JC ;
WALFORD, GD ;
MIDEI, MG ;
FLAHERTY, JT ;
WEISS, JL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (07) :1594-1600
[9]   LACK OF MYOCARDIAL PERFUSION IMMEDIATELY AFTER SUCCESSFUL THROMBOLYSIS - A PREDICTOR OF POOR RECOVERY OF LEFT-VENTRICULAR FUNCTION IN ANTERIOR MYOCARDIAL-INFARCTION [J].
ITO, H ;
TOMOOKA, T ;
SAKAI, N ;
YU, H ;
HIGASHINO, Y ;
FUJII, K ;
MASUYAMA, T ;
KITABATAKE, A ;
MINAMINO, T .
CIRCULATION, 1992, 85 (05) :1699-1705
[10]   ASSESSMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW WITH MYOCARDIAL CONTRAST TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
KAUL, S ;
KELLY, P ;
OLINER, JD ;
GLASHEEN, WP ;
KELLER, MW ;
WATSON, DD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (02) :468-482