ADSORPTIVE STRIPPING VOLTAMMETRY FOR DETERMINATION OF TRACE AMOUNTS OF ALUMINUM USING SOLOCHROME VIOLET RS COMPLEX

被引:0
|
作者
STRYJEWSKA, E
RUBEL, S
KUSMIERCZYK, K
机构
来源
CHEMIA ANALITYCZNA | 1992年 / 37卷 / 01期
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination was carried out in 0.2 mol l-1 acetate buffer (pH 4.2) in the presence of 10(-5) mol l-1 solution of Solochrome Violet RS. For complete formation of the complex the sample was heated for 10 min at 90-degrees-C. Adsorptive preconcentration was made on mercury drop electrode at -0.25V during 1 min and the cathodic peaks were recorded from -0.25 to -0.8 V The interference of iron(III) was removed by reduction with hydrazine hydrochloride; other heavy metals including copper were removed by electrolysis on mercury macroelectrode. The calibration graph was found to be linear from 1 to 15 ppb Al. This method was applied for determination of aluminium in water, snow, medical aqueous preparations and lung tissue. The accuracy was tested using flour V-8 standard reference material.
引用
收藏
页码:43 / 49
页数:7
相关论文