Radiation exposure during cardiac catheterization: Implications for the transradial approach

被引:3
作者
Komocsi, A. [1 ]
Konyi, A. [1 ]
Kovacs, E. [2 ]
Ungi, I. [3 ]
机构
[1] Univ Pecs, Fac Med, Heart Inst, Pecs, Hungary
[2] State Hosp Cardiol, Dept Cardiol, Balatonfured, Hungary
[3] Univ Szeged, Fac Med, Dept Cardiol, Szeged, Hungary
关键词
cardiac catheterization; safety; radioprotection; transradial approach; learning curve;
D O I
10.1556/IMAS.2.2010.3.3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary angiography and intervention became an integral part of the modern cardiology. These invasive procedures beside their firmly established benefits also expose the patient to a hazard for access site complication, contrast material and radiation exposure. Transradial access significantly reduces the risk associated with the arterial puncture; however its effect regarding the radiation exposure is debated. Our aim was to review the aspects of transradial coronary intervention in the context of the radiation exposure. This review focuses on key aspects of feasibility and safety related to the access site choice and the learning curve.
引用
收藏
页码:105 / 109
页数:5
相关论文
共 32 条
[1]   Radial versus femoral approach for percutaneous coronary diagnostic and interventional procedures - Systematic overview and meta-analysis of randomized trials [J].
Agostoni, P ;
Biondi-Zoccai, GGL ;
De Benedictis, ML ;
Rigattieri, S ;
Turri, M ;
Anselmi, M ;
Vassanelli, C ;
Zardini, P ;
Louvard, Y ;
Hamon, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (02) :349-356
[2]   A pilot study exploring the possibility of establishing guidance levels in x-ray directed interventional procedures [J].
Baiter, S. ;
Miller, D. L. ;
Vano, E. ;
Lopez, P. Ortiz ;
Bernardi, G. ;
Cotelo, E. ;
Faulkner, K. ;
Nowotny, R. ;
Padovani, R. ;
Ramirez, A. .
MEDICAL PHYSICS, 2008, 35 (02) :673-680
[3]   Impact of Final Activated Clotting Time After Transradial Coronary Stenting With Maximal Antiplatelet Therapy [J].
Bertrand, Olivier F. ;
Rodes-Cabau, Josep ;
Rinfret, Stephane ;
Larose, Eric ;
Bagur, Rodrigo ;
Proulx, Guy ;
Gleeton, Onil ;
Costerousse, Olivier ;
De Larochelliere, Robert ;
Roy, Louis .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (09) :1235-1240
[4]   Incidence, predictors, and clinical impact of bleeding after transradial coronary stenting and maximal antiplatelet therapy [J].
Bertrand, Olivier F. ;
Larose, Eric ;
Rodes-Cabau, Josep ;
Gleeton, Onil ;
Taillon, Isabelle ;
Roy, Louis ;
Poirier, Paul ;
Costerousse, Olivier ;
De Larochelliere, Robert .
AMERICAN HEART JOURNAL, 2009, 157 (01) :164-169
[5]   Comparison of operator radiation exposure with optimized radiation protection devices during coronary angiograms and ad hoc percutaneous coronary interventions by radial and femoral routes [J].
Brasselet, Camille ;
Blanpain, Thierry ;
Tassan-Mangina, Sophie ;
Deschildre, Alain ;
Duval, Sebastien ;
Vitry, Fabien ;
Gaillot-Petit, Nathalie ;
Clement, Jean Paul ;
Metz, Damien .
EUROPEAN HEART JOURNAL, 2008, 29 (01) :63-70
[6]   PERCUTANEOUS RADIAL ARTERY APPROACH FOR CORONARY ANGIOGRAPHY [J].
CAMPEAU, L .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 16 (01) :3-7
[7]   Association of the arterial access site at angioplasty with transfusion and mortality: the MORTAL study (Mortality benefit Of Reduced Transfusion after percutaneous coronary intervention via the Arm or Leg) [J].
Chase, A. J. ;
Fretz, E. B. ;
Warburton, W. P. ;
Klinke, W. P. ;
Carere, R. G. ;
Pi, D. ;
Berry, B. ;
Hilton, J. D. .
HEART, 2008, 94 (08) :1019-1025
[8]   Effect of transradial access on quality of life and cost of cardiac catheterization: A randomized comparison [J].
Cooper, CJ ;
El-Shiekh, RA ;
Cohen, DJ ;
Blaesing, L ;
Burket, MW ;
Basu, A ;
Moore, JA .
AMERICAN HEART JOURNAL, 1999, 138 (03) :430-436
[9]   Right versus left radial artery approach for coronary angiography.: Differences observed and the learning curve [J].
Fernandez-Portales, Javier ;
Valdesuso, Raul ;
Carreras, Raul ;
Jimenez-Candil, Javier ;
Serrador, Ana ;
Romani, Sebastian .
REVISTA ESPANOLA DE CARDIOLOGIA, 2006, 59 (10) :1071-1074
[10]  
Gioia G, 2000, CATHETER CARDIO INTE, V51, P234, DOI 10.1002/1522-726X(200010)51:2<234::AID-CCD22>3.0.CO