Transconjunctival sutureless 23-gauge vitrectomy for vitreoretinal diseases: Outcome of 30 consecutive cases

被引:6
作者
El-Batarny, Ashraf M. [1 ]
机构
[1] Magrabi Eye & Ear Hosp, Dept Ophthalmol, Muscat, Oman
关键词
23-gauge vitrectomy; transconjunctival sutureless vitrectomy; vitreoretinal surgery;
D O I
10.4103/0974-9233.51983
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background : To describe the initial experience, effectiveness, and safety profile of 23-gauge instrumentation for a variety of vitreoretinal conditions. Methods : A retrospective review of 30 consecutive 23-gauge vitrectomy cases done by a single vitreoretinal surgeon for various posterior segment conditions was done. All surgeries were performed using the two-step 23-gauge system developed by Dutch Ophthalmic Research Center (DORC). All patients had at least 3-month follow-up. Main outcome measures included surgical success, visual acuity, intraocular pressure, and operative complications. Results : Mean follow-up was 7.7 months (range 3-12 months). Indications for surgery included rhegmatogenous retinal detachment (n=8), nonclearing vitreous hemorrhage (n=6), tractional retinal detachment (n=5), macular hole (n=5), epiretinal membrane (n=3), retained lens fragments (n=2) and endophthalmitis (n=1). Gas tamponade was used in 18 eyes (60%) and silicone oil in six eyes (20%). Mean overall preoperative visual acuity was 20/1053 and final acuity was 20/78 ( P = 0.001). Mean intraocular pressure after 6 hours was 15.1mmHg (range 4-25 mmHg) and on postoperative day one was 14.5 mmHg (range 2-21 mmHg). Four eyes (13.3%) required suturing of sclerotomy intraoperatively. Conversion to 20-gauge was done in one eye (3.3%). Hypotony was reported in one eye (3.3%) postoperatively. Subconjunctival silicone oil reported in one eye (3.3%). There were no postoperative complications of endophthalmitis, retinal or choroidal detachment. Conclusion : 23-gauge transconjunctival sutureless vitrectomy was effective in the management of wide variety of vitreoretinal surgical indications. The safety profile compared favorably with published rates for 25-gauge systems.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 19 条
[1]   Reversed self-sealing pars plana sclerotomies [J].
Assi, AC ;
Scott, RAH ;
Charteris, DG .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2000, 20 (06) :689-692
[2]   Sutureless pars plana vitrectomy through self-sealing sclerotomies [J].
Chen, JC .
ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (10) :1273-1275
[3]   Transconjunctival sutureless 23-gauge vitrectomy [J].
Eckardt, C .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2005, 25 (02) :208-211
[4]   Initial experience using the Transconjunctival Sutureless Vitrectomy System for vitreoretinal surgery [J].
Fujii, GY ;
de Juan, E ;
Humayun, MS ;
Chang, TS ;
Pieramici, DJ ;
Barnes, A ;
Kent, D .
OPHTHALMOLOGY, 2002, 109 (10) :1814-1820
[5]  
Fujii GY, NEW 25 GAUGE INSTRUM
[6]   Longer-term outcomes of transconjunctival sutureless 25-gauge vitrectomy [J].
Ibarra, MS ;
Hermel, M ;
Prenner, JL ;
Hassan, TS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (05) :831-836
[7]   Modified sutureless sclerotomies in pars plana vitrectomy [J].
Jackson, T .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (01) :116-117
[8]   Modified sutureless sclerotomies in pars plana vitrectomy [J].
Kwok, AKH ;
Tham, CCY ;
Lam, DSC ;
Li, M ;
Chen, JC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (06) :731-733
[9]   Outcomes of 140 consecutive cases of 25-gauge transconjunctival surgery for posterior segment disease [J].
Lakhanpal, RR ;
Humayun, MS ;
de Juan, E ;
Lim, JI ;
Chong, LP ;
Chang, TS ;
Javaheri, M ;
Fujii, GY ;
Barnes, AC ;
Alexandrou, TJ .
OPHTHALMOLOGY, 2005, 112 (05) :817-824
[10]  
Lam DSC, 2003, OPHTHALMOLOGY, V110, P2428, DOI 10.1016/j.ophtha.2003.09.006