Computed Radiography and Dosimetry: Some Practical Tips for Dose Optimization Procedures

被引:4
作者
Davidson, Rob [1 ]
Sim, Jenny [1 ]
机构
[1] RMIT Univ, Sch Med Sci Med Radiat, POB 71, Melbourne, Vic 3083, Australia
关键词
D O I
10.1016/j.jmir.2008.07.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article provides some practical tips for dose optimization in computed radiography (CR). The article will not provide a comprehensive list of all factors that could be changed to optimize patient dose in CR examination. This article will also provide specific manufacturer examples that can be transferred to other manufacturers' CR systems. Due to the relatively large dynamic range of CR, stringent measures have to be put in place to ensure that patients are not being overexposed to ionizing radiation. Manufacturers of CR systems use dose indicators such as S-values, exposure index, and log-mean values to provide an indication of the "dose" received at the imaging plate. Manufacturers also provide a histogram analysis of the image pixel values. This histogram can also be used to evaluate the dose. The dose received at the imaging plate also has an effect on image quality. Radiographic factors of kV, mAs, and source to image distance affect the dose index, the histogram, and hence the image quality. These relationships will be reviewed and practical tips for dose optimization will be discussed.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 29 条
  • [1] Optimization of dose and image quality for computed radiography and digital radiography
    Aldrich, JE
    Duran, E
    Dunlop, P
    Mayo, JR
    [J]. JOURNAL OF DIGITAL IMAGING, 2006, 19 (02) : 126 - 131
  • [2] Development of dosimetry using detectors of diagnostic digital radiography systems
    Ariga, Eiji
    Ito, Shigeki
    Deji, Shizuhiko
    Saze, Takuya
    Nishizawa, Kunihide
    [J]. MEDICAL PHYSICS, 2007, 34 (01) : 166 - 174
  • [3] Artz DS, 1997, SEMIN ROENTGENOL, V32, P12
  • [4] Balter S., 1990, DIGITAL IMAGING DIAG, P81
  • [5] Effect of x-ray tube potential on image quality and patient dose for lumbar spine computed radiography examinations
    Brindhaban A.
    Al Khalifah K.
    Al Wathiqi G.
    Al Ostath H.
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2005, 28 (4): : 216 - 222
  • [6] Image quality and dose management in digital radiography: A new paradigm for optimisation
    Busch, HP
    Faulkner, K
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 143 - 147
  • [7] Bushberg J. T., 2011, ESSENTIAL PHYS MED I
  • [8] Artefacts found in computed radiography
    Cesar, LJ
    Schueler, BA
    Zink, FE
    Daly, TR
    Taubel, JP
    Jorgenson, LL
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (878) : 195 - 202
  • [9] Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector
    Dobbins, JT
    Samei, E
    Chotas, HG
    Warp, RJ
    Baydush, AH
    Floyd, CE
    Ravin, CE
    [J]. RADIOLOGY, 2003, 226 (01) : 221 - 230
  • [10] Flat panel digital radiography compared with storage phosphor computed radiography - Assessment of dose versus image quality in phantom studies
    Fischbach, F
    Ricke, J
    Freund, T
    Werk, M
    Spors, B
    Baumann, C
    Pech, M
    Felix, R
    [J]. INVESTIGATIVE RADIOLOGY, 2002, 37 (11) : 609 - 614