MOTION ASSOCIATED SUSCEPTIBILITY ARTIFACTS

被引:0
|
作者
BACHGANSMO, T [1 ]
ERICSSON, A [1 ]
LEANDER, P [1 ]
FAHLVIK, AK [1 ]
HEMMINGSSON, A [1 ]
机构
[1] NYCOMED AS,OSLO,NORWAY
关键词
MAGNETIC RESONANCE (MR); ARTIFACT; -; EXPERIMENTAL; CONTRAST ENHANCEMENT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A bowel labeling agent is important for improving abdominal MR. Besides providing contrast between the bowel and other organs, the contrast agent itself is a potential source of artifacts. The artifacts created by superparamagnetic particles (SPP) subjected to motion have been studied in vitro at 0.5 T, and compared to artifacts created by a paramagnetic compound. Apart from the expected static effects of the SPP, movement induced additional artifacts were seen as signal displacements in the phase-encoding direction. The artifacts were obvious at an iron concentration of 1 mg Fe/ml, barely visible at 0.2 mg Fe/ml, and completely absent at 0.1 mg Fe/ml. Artifacts were also evident with the SPP outside the imaging slice. This further emphasizes the importance of choosing the lowest effective dose when using SPP contrast agents. For the paramagnetic agent, motion propagated artifacts consisted of high and low signal regions in a mosaic pattern.
引用
收藏
页码:606 / 610
页数:5
相关论文
共 50 条
  • [21] A wavelet method for modeling and despiking motion artifacts from resting-state fMRI time series
    Patel, Ameera X.
    Kundu, Prantik
    Rubinov, Mikail
    Jones, P. Simon
    Vertes, Petra E.
    Ersche, Karen D.
    Suckling, John
    Bullmore, Edward T.
    NEUROIMAGE, 2014, 95 : 287 - 304
  • [22] Motion artifacts in cardiac CT - The Novacor left ventricular assist device and its implications for clinical imaging
    Knollman, FD
    Halfmann, R
    Regn, J
    Loebe, M
    Ewert, R
    Hetzer, R
    Felix, R
    ACTA RADIOLOGICA, 1999, 40 (06) : 569 - 577
  • [23] Reduction of motion artifacts in magnetic resonance imaging of the neck and cervical spine by long-term averaging
    Seitz, J
    Strotzer, M
    Völk, M
    Held, P
    Djavidani, B
    Nitz, WR
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 2000, 35 (06) : 380 - 384
  • [24] Motion artifacts in subsecond conventional CT and electron-beam CT: Pictorial demonstration of temporal resolution
    McCollough, CH
    Bruesewitz, MR
    Daly, TR
    Zink, FE
    RADIOGRAPHICS, 2000, 20 (06) : 1675 - 1681
  • [25] Signal intensity artifacts in clinical MR imaging
    Jones, RW
    Witte, RJ
    RADIOGRAPHICS, 2000, 20 (03) : 893 - 901
  • [26] ICA-AROMA: A robust ICA-based strategy for removing motion artifacts from fMRI data
    Pruim, Raimon H. R.
    Mennes, Maarten
    van Rooij, Daan
    Llera, Alberto
    Buitelaar, Jan K.
    Beckmann, Christian F.
    NEUROIMAGE, 2015, 112 : 267 - 277
  • [27] Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
    Medhat M. Osman
    Christian Cohade
    Yuji Nakamoto
    Richard L. Wahl
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 603 - 606
  • [28] Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
    Osman, MM
    Cohade, C
    Nakamoto, Y
    Wahl, RL
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) : 603 - 606
  • [29] Optimal ECG trigger point in electron-beam CT studies: Three methods for minimizing motion artifacts
    Mao, SS
    Budoff, MJ
    Bin, L
    Liu, SCK
    ACADEMIC RADIOLOGY, 2001, 8 (11) : 1107 - 1115
  • [30] Three-dimensional quantification of magnetic resonance imaging artifacts associated with shape factors
    Kawabata, Iku
    Imai, Haruki
    Kanno, Zuisei
    Tetsumura, Akemi
    Tsutsumi, Yusuke
    Doi, Hisashi
    Ashida, Maki
    Kurabayashi, Tohru
    Hanawa, Takao
    Yamamoto, Toru
    Ono, Takashi
    DENTAL MATERIALS JOURNAL, 2019, 38 (04) : 638 - 645