POLYMER ABLATION WITH A HIGH-POWER EXCIMER-LASER TOOL

被引:5
|
作者
WOLBOLD, GE
TESSLER, CL
TUDRYN, DJ
机构
[1] IBM Technology Products, Hopewell Junction
关键词
LASER ABLATION; EXCIMER LASER; VIA FORMATION PACKAGING; PROCESSING POLYMERS; DIELECTRIC MASK;
D O I
10.1016/0167-9317(93)90203-H
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A high-power excimer laser projection ablation tool and process in a manufacturing line is described. The light source is a 150 W XeCl (308 nm) gas laser. The projection ablation unit is very similar to that of a photo expose tool and comparisons will be made. The laser, beam delivery system, projection optics, beam homogenization, system accuracy (overlay), tool, process, operation, control, and system reliability will be discussed.
引用
收藏
页码:3 / 14
页数:12
相关论文
共 50 条
  • [31] SURFACE QUALITY OF EXCIMER-LASER CORNEAL ABLATION WITH DIFFERENT FREQUENCIES
    LIANG, FQ
    ISHIKAWA, T
    KIM, J
    DELCERRO, M
    PARK, SB
    AQUAVELLA, JV
    CORNEA, 1993, 12 (06) : 500 - 506
  • [32] Mechanism for excimer-laser ablation in alkaline-earth metals
    Nishikawa, H
    Kanai, M
    Szabo, G
    Kawai, T
    PHYSICAL REVIEW B, 2000, 61 (02): : 967 - 973
  • [33] CORNEAL ENDOTHELIAL DAMAGE AFTER DEEP EXCIMER-LASER ABLATION
    KIM, K
    KIM, G
    OH, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S298 - S298
  • [34] CORNEAL SENSITIVITY AND NERVE REGENERATION AFTER EXCIMER-LASER ABLATION
    ISHIKAWA, T
    DELCERRO, M
    LIANG, FQ
    LOYA, N
    AQUAVELLA, JV
    CORNEA, 1994, 13 (03) : 225 - 231
  • [35] DEPOSITION OF HIGH-QUALITY TIN FILMS BY EXCIMER-LASER ABLATION IN REACTIVE GAS
    MIHAILESCU, IN
    CHITICA, N
    NISTOR, LC
    POPESCU, M
    TEODORESCU, VS
    URSU, I
    ANDREI, A
    BARBORICA, A
    LUCHES, A
    DEGIORGI, ML
    PERRONE, A
    DUBREUIL, B
    HERMANN, J
    JOURNAL OF APPLIED PHYSICS, 1993, 74 (09) : 5781 - 5789
  • [36] PHOTOREFRACTIVE ABLATION WITH EXCIMER-LASER AND CORNEAL PERMEABILITY MEASURED BY FLUOROPHOTOMETRY
    MURILLO, AI
    SUAREZ, R
    REYNOSO, M
    GRAUE, E
    RAMIREZ, T
    CLIMENT, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S709 - S709
  • [37] ABLATION OF THE CORNEA BY USING A LOW-ENERGY EXCIMER-LASER
    UNKROTH, A
    KLEINSCHMIDT, J
    ZIEGLER, W
    HOFMANN, B
    JUTTE, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1993, 231 (05) : 303 - 307
  • [38] DYNAMICS OF ABLATION PLUME PARTICLES GENERATED DURING EXCIMER-LASER CORNEAL ABLATION
    HAHN, DW
    EDIGER, MN
    PETTIT, GH
    LASERS IN SURGERY AND MEDICINE, 1995, 16 (04) : 384 - 389
  • [39] BLAST-WAVE STUDIES OF EXCIMER-LASER ABLATION OF ZNS
    DYER, PE
    KEY, PH
    SANDS, D
    SNELLING, HV
    WAGNER, FX
    APPLIED SURFACE SCIENCE, 1995, 86 (1-4) : 18 - 23
  • [40] EFFECT OF DEPTH UPON THE SMOOTHNESS OF EXCIMER-LASER CORNEAL ABLATION
    TAYLOR, SM
    FIELDS, CR
    BARKER, FM
    SANZO, J
    OPTOMETRY AND VISION SCIENCE, 1994, 71 (02) : 104 - 108