Arterial waveform analysis

被引:69
作者
Esper, Stephen A. [1 ]
Pinsky, Michael R. [1 ,2 ]
机构
[1] Univ Pittsburgh, Dept Anesthesiol, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Crit Care Med, Pittsburgh, PA USA
关键词
arterial waveform; arterial line; minimally invasive monitoring; devices; cardiac output; stroke volume variation;
D O I
10.1016/j.bpa.2014.08.002
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The bedside measurement of continuous arterial pressure values from waveform analysis has been routinely available via indwelling arterial catheterization for >50 years. Invasive blood pressure monitoring has been utilized in critically ill patients, in both the operating room and critical care units, to facilitate rapid diagnoses of cardiovascular insufficiency and monitor response to treatments aimed at correcting abnormalities before the consequences of either hypo-or hypertension are seen. Minimally invasive techniques to estimate cardiac output (CO) have gained increased appeal. This has led to the increased interest in arterial waveform analysis to provide this important information, as it is measured continuously in many operating rooms and intensive care units. Arterial waveform analysis also allows for the calculation of many so-called derived parameters intrinsically created by this pulse pressure profile. These include estimates of left ventricular stroke volume(SV), CO, vascular resistance, and during positive-pressure breathing, SV variation, and pulse pressure variation. This article focuses on the principles of arterial waveform analysis and their determinants, components of the arterial system, and arterial pulse contour. It will also address the advantage of measuring real-time CO by the arterial waveform and the benefits to measuring SV variation. Arterial waveform analysis has gained a large interest in the overall assessment and management of the critically ill and those at a risk of hemodynamic deterioration. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:363 / 380
页数:18
相关论文
共 149 条
[1]  
Abrams JH, 1989, CARDIOPULMONARY MONI
[2]  
Am Soc Anesthesiologists Task Forc, 2003, ANESTHESIOLOGY, V99, P988
[3]  
Ameloot K, 2014, MINERVA ANESTESIOL
[4]  
[Anonymous], 1997, PLUS MAG
[5]   Cardiac Index Assessment by the Pressure Recording Analytic Method in Critically Ill Unstable Patients After Cardiac Surgery [J].
Barille, Luigi ;
Landoni, Giovanni ;
Pieri, Marina ;
Ruggeri, Laura ;
Maj, Giulia ;
Nigro Neto, Caetano ;
Pasin, Laura ;
Cabrini, Luca ;
Zangrillo, Alberto .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) :1108-1113
[6]   NONINVASIVE CARDIAC OUTPUT MONITORING DURING EXERCISE TESTING: NEXFIN PULSE CONTOUR ANALYSIS COMPARED TO AN INERT GAS REBREATHING METHOD AND RESPIRED GAS ANALYSIS [J].
Bartels, Sebastiaan A. ;
Stok, Wim J. ;
Bezemer, Rick ;
Boksem, Remco J. ;
van Goudoever, Jeroen ;
Cherpanath, Thomas G. V. ;
van Lieshout, Johannes J. ;
Westerhof, Berend E. ;
Karemaker, John M. ;
Ince, Can .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2011, 25 (05) :315-321
[7]   Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output [J].
Bein, B ;
Worthmann, F ;
Tonner, PH ;
Paris, A ;
Steinfath, M ;
Hedderich, J ;
Scholz, J .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2004, 18 (02) :185-189
[8]   Complications related to less-invasive haemodynamic monitoring [J].
Belda, F. J. ;
Aguilar, G. ;
Teboul, J. L. ;
Pestana, D. ;
Redondo, F. J. ;
Malbrain, M. ;
Luis, J. C. ;
Ramasco, F. ;
Umgelter, A. ;
Wendon, J. ;
Kirov, M. ;
Fernandez-Mondejar, E. .
BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (04) :482-486
[9]   Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients [J].
Bendjelid, K. ;
Marx, G. ;
Kiefer, N. ;
Simon, T. P. ;
Geisen, M. ;
Hoeft, A. ;
Siegenthaler, N. ;
Hofer, C. K. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (04) :573-579
[10]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984