PEDICLE MORPHOLOGY OF THE LOWER THORACIC AND LUMBAR SPINE IN A CHINESE POPULATION

被引:107
作者
HOU, SX [1 ]
HU, R [1 ]
SHI, YM [1 ]
机构
[1] POSTGRAD MED COLL,TRAUMA HOSP 304TH PLA,DEPT ORTHOPAED,BEIJING,PEOPLES R CHINA
关键词
PEDICLE; MORPHOLOGY; GENDER DIFFERENCES; POPULATION DIFFERENCES;
D O I
10.1097/00007632-199310000-00021
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Knowledge of pedicle diameter and surface landmarks is crucial for safe placement of screws. Little attention has been paid to variations of entrance points for pedicle screws, differentiation of male and female pedicle sizes and pedicle size differences in nonwhite populations. Forty thoracolumbar spinal columns from T9 to L5 were measured using vernier calipers. Cephalad-caudad and medial-lateral diameter of the pedicle, length of the pedicle from posterior cortex to anterior cortex at the midline and parallel to midline was measured. Relation of the centre of the pedicle to the transverse process (TP) and to the superior facet joint was noted. Twenty-five male and 15 female specimens were measured. Average pedicle width in the female was 5.2 mm at T9 (SD 0.9) to 13 mm at L5 (SD 2.7) and in the male 6.0 mm at T9 (SD 1.1) to 12.8 mm at L5 (SD 2.7). Cephalad caudad diameter was 12.5 mm (SD 1.2) at T9 to 20.5 mm (SD 3.6) at L5 in the male and in the female 12.2 mm (SD 1.3) at T9 to 18.7 mm (SD 3.9) at L5. All specimens had starting points cephalad to the midpoint of the TP at T9. At L5, 37 of 40 specimens had starting points at the midpoint of the TP. Starting points were parallel to the middle or lateral third of the superior facet joint at T9. At L5 starting points were at least one third of the facet joint lateral to the lateral border of the facet. Female pedicle width was smaller than male at T9 (P = 0.03) and Tl 2 (P = 0.04). All pedicle widths except Tl 1 are significantly smaller than the white population as measured by Zindrick et al. Male pedicle widths are significantly smaller than whites as measured by Olsewski et al. Only L5 is smaller than the white population as measured by Berry et al. Starting points should be more lateral in the low lumbar spine. Pedicle screw insertion depends on the sex and size of the patient, and the location of the vertebrae.
引用
收藏
页码:1850 / 1855
页数:6
相关论文
共 11 条
  • [1] Berry J.L., Moran J.M., Berg W.S., Steffee A.D., A morphometric study of human lumbar and selected thoracic vertebrae, Spine, 12, 4, pp. 362-367, (1987)
  • [2] Krag M.H., Beynonn B.D., Pope M.H., Frymoyer J.W., Haugh L.D., Weaver D.L., An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine, CORR, 203, pp. 76-98, (1986)
  • [3] Louis R., Fusion of the lumbar and sacral spine by internal fixation with screw plates, CORR, 203, pp. 18-33, (1986)
  • [4] Magerl F., External skeletal fixation of the lower thoracic and the lumbar spine, Current Concepts of External Fixation of Fractures, (1982)
  • [5] Olsewski J.M., Simmons E.H., Kallen F.C., Mendel F.C., Severin C.M., Berens D.L., Morphometry of the lumbar spine: Anatomical perspectives related to transpedicular fixation, J Bone Joint Surg, 72A, 4, pp. 541-549, (1990)
  • [6] Roy-Camille R., Operative Technique: Pedicular Screw Plating of Thoracic, Thoracolumbar, and Lumbar Injuries. BG, (1989)
  • [7] Schlapfer F., Worsdorfer O., Magerl F., Perren S.M., Stabilization of the lower thoracic and lumbar spine, Current Concepts of External Fixation of Fractures, (1982)
  • [8] Steffe A., Biscup R., Sitkowski D., Segmental spine plates with pedicle screw fixation: A new internal fixation device for disorders of the lumbar and thoracic spine, CORR, 203, (1986)
  • [9] Weinstein J.N., Spratt K.F., Spengler D., Black C., Reid S., Spinal pedicle fixation: Reliability and validity of roentgenogram- based assessment and surgical factors on successful screw placement, Spine, 13, 9, pp. 1012-1018, (1988)
  • [10] Zindrick M.R., Wiltse L.L., Doornik A., Et al., Analysis of the morphometric characteristics of the thoracic and lumbar pedicles, Spine, 12, 2, pp. 160-166, (1987)