SEPARATION OF PCB CONGENERS USING ACTIVE COAL COLUMNS

被引:14
作者
ATUMA, SS
ANDERSSON, O
机构
[1] National Food Administration, S-751 26 Uppsala
关键词
ACTIVE COAL; COPLANAR PCB; DUAL COLUMN;
D O I
10.1016/0045-6535(93)90269-B
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The affinity of active coal for the planar PCBs has been utilized to effect a structural separation of these congeners from the rest of the PCBs, thereby eliminating potential interferents and improving the quality of analytical data. With two conventional active coal columns, non-ortho, mono-ortho and di-ortho substituted chlorobiphenyls (PCB) in a sample extract, are separated into three distinct fractions. Congener identification, quantification and confirmation are carried out partly by dual-column high resolution GC/ECD, and partly by GC/MS (non-ortho PCB congeners). The method has been applied to herring samples and, among the PCB congeners determined, are IUPAC No 77, 126, 169 (non-ortho PCBs), 118, 105, 156 (mono-ortho PCBs) and 52, 101, 110, 153, 138 and 180 (di-ortho PCBs).
引用
收藏
页码:1 / 8
页数:8
相关论文
共 17 条
[1]   FRACTIONATION OF POLYCHLORINATED-BIPHENYLS, POLYCHLORINATED DIBENZO-PARA-DIOXINS, AND POLYCHLORINATED DIBENZOFURANS ON POROUS GRAPHITIC CARBON [J].
CREASER, CS ;
ALHADDAD, A .
ANALYTICAL CHEMISTRY, 1989, 61 (11) :1300-1302
[2]   BIOLOGICAL-ACTIVITY, DETERMINATION AND OCCURRENCE OF PLANAR, MONO-ORTHO AND DI-ORTHO PCBS [J].
DEVOOGT, P ;
WELLS, DE ;
REUTERGARDH, L ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 40 (1-4) :1-46
[3]   MULTIDIMENSIONAL GAS-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION FOR THE DETERMINATION OF TOXIC CONGENERS IN POLYCHLORINATED BIPHENYL MIXTURES [J].
DUINKER, JC ;
SCHULZ, DE ;
PETRICK, G .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :478-482
[4]   SIMULTANEOUS DUAL-COLUMN, DUAL-DETECTOR GAS-CHROMATOGRAPHIC DETERMINATION OF CHLORINATED PESTICIDES AND POLYCHLORINATED-BIPHENYLS IN ENVIRONMENTAL-SAMPLES [J].
DURELL, GS ;
SAUER, TC .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1867-1871
[5]  
Erickson M.D., 1986, ANAL CHEM PCBS
[6]   ISOLATION OF TOXIC POLYCHLORINATED-BIPHENYLS BY ELECTRON-DONOR ACCEPTOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON A 2-(1-PYRENYL)ETHYLDIMETHYLSILYLATED SILICA COLUMN [J].
HAGLUND, P ;
ASPLUND, L ;
JARNBERG, U ;
JANSSON, B .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :389-398
[7]   A METHOD FOR THE DETERMINATION OF PCB CONGENERS 77, 126 AND 169 IN BIOTIC AND ABIOTIC MATRICES [J].
HARRAD, SJ ;
SEWART, AS ;
BOUMPHREY, R ;
DUARTEDAVIDSON, R ;
JONES, KC .
CHEMOSPHERE, 1992, 24 (08) :1147-1154
[8]   DETERMINATION OF MONO-ORTHO AND NON-ORTHO COPLANAR PCBS IN FISH [J].
HONG, CS ;
BUSH, B .
CHEMOSPHERE, 1990, 21 (1-2) :173-181
[9]  
Jensen S., 1972, Ambio Spec Rep, VNo. 1, P71
[10]   A COMPARISON BETWEEN ACTIVATED CHARCOALS AND MULTIDIMENSIONAL GC IN THE SEPARATION AND DETERMINATION OF (NON-ORTHO CL SUBSTITUTED) TOXIC CHLOROBIPHENYLS [J].
KANNAN, N ;
PETRICK, G ;
SCHULZ, D ;
DUINKER, J ;
BOON, J ;
VANARNHEM, E ;
JANSEN, S .
CHEMOSPHERE, 1991, 23 (8-10) :1055-1076