THERMOSPRAY NEBULIZATION AS SAMPLE INTRODUCTION FOR INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY

被引:26
作者
VANHOE, H
MOENS, L
DAMS, R
机构
[1] Laboratory of Analytical Chemistry, University of Ghent, Institute for Nuclear Sciences, 8-9000 Ghent
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; SAMPLE INTRODUCTION; THERMOSPRAY NEBULIZATION;
D O I
10.1039/ja9940900815
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sample introduction system, consisting of a thermospray nebulizer and a desolvating unit, was coupled to an inductively coupled plasma mass spectrometer. Several parameters were optimized including the sample uptake rate, the power delivered to the capillary tube, the temperature of the aerosol and of the cooling-water, the carrier gas flow rate and the r.f. power. Under optimized conditions, the sensitivity obtained with the thermospray system is a factor of 10 higher than with a pneumatic nebulizer combined with a spray chamber. The increase was observed for the following elements over the whole mass range: Be, Al, Sc, Co, In, Gd, Tl, Th and U. Since similar background levels, 10-40 counts s-1, were observed, better detection limits could be achieved (from 0.19 ng l-1 for U to 1.3 ng l-1 for Be). The relative standard deviation (RSD) on analyte signals for a short-term stability test (10 min) is between 3 and 8%. These values can be improved to less than 4% by the use of internal standardization. No drift in analyte signal during several hours was observed. The levels of oxide (MO+:M+) and doubly charged (M2+:M+) ions obtained with the thermospray system are about a factor of 2.5 lower than those obtained with the pneumatic system. Consequently, the oxide ion levels for elements with the highest MO bond strength and the doubly charged ion levels for elements with the lowest second ionization energy are not above 1%.
引用
收藏
页码:815 / 821
页数:7
相关论文
共 21 条
[1]   THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLAKLEY, CR ;
VESTAL, ML .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :750-754
[2]   SAMPLE INTRODUCTION - THE ACHILLES HEEL OF ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A786-&
[3]  
ELGERSMA JW, 1991, SPECTROCHIM ACTA B, V46, P1973
[4]   LANGMUIR PROBE POTENTIAL MEASUREMENTS IN THE PLASMA AND THEIR CORRELATION WITH MASS-SPECTRAL CHARACTERISTICS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GRAY, AL ;
HOUK, RS ;
WILLIAMS, JG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (01) :13-20
[5]   ANALYTICAL IMPROVEMENT OF PNEUMATIC NEBULIZATION IN ICP-MS BY DESOLVATION [J].
JAKUBOWSKI, N ;
FELDMANN, I ;
STUEWER, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (01) :107-118
[6]   HYDRAULIC HIGH-PRESSURE NEBULIZATION - APPLICATION OF A NEW NEBULIZATION SYSTEM FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
JAKUBOWSKI, N ;
FELDMANN, I ;
STUEWER, D ;
BERNDT, H .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (01) :119-129
[7]   FUNDAMENTAL CHARACTERISTICS OF THERMOSPRAY AEROSOLS AND SAMPLE INTRODUCTION FOR ATOMIC SPECTROMETRY [J].
KOROPCHAK, JA ;
WINN, DH .
APPLIED SPECTROSCOPY, 1987, 41 (08) :1311-1318
[8]   EFFECTS OF CAPILLARY DIAMETER ON THERMOSPRAY SAMPLE INTRODUCTION TO INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
KOROPCHAK, JA ;
ARYAMANYAMUGISHA, H ;
WINN, DH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :799-802
[9]  
MEYER GA, 1985, ICP INFORMATION NEWS, V10, P955
[10]   ARGON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH THERMOSPRAY, ULTRASONIC, AND PNEUMATIC NEBULIZATION [J].
MONTASER, A ;
TAN, H ;
ISHII, I ;
NAM, SH ;
CAI, MX .
ANALYTICAL CHEMISTRY, 1991, 63 (22) :2660-2665