DIGITAL DYNAMIC-RANGE EXPANSION APPLIED TO X-RAY DENSITOMETRIC ANALYSIS OF TOTAL HIP-REPLACEMENT

被引:10
作者
VICECONTI, M
BARUFFALDI, F
GAIBA, W
TONI, A
SUDANESE, A
GIUNTI, A
机构
[1] S ORSOLA CLIN,DEPT HLTH PHYS,BOLOGNA,ITALY
[2] UNIV BOLOGNA,RIZZOLI INST,ORTHOPAED CLIN,I-40126 BOLOGNA,ITALY
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1993年 / 15卷 / 01期
关键词
HIP PROSTHESIS; DENSITOMETRY; BONE REMODELING; IMAGE ANALYSIS;
D O I
10.1016/0141-5425(93)90094-F
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Due to the presence of the stiff prosthetic stem fitted in the medullary canal during total his replacement, the surrounding cortex of the femur changes its density over time. This bone remodelling takes place with every type of total hip prosthesis; however, its intensity may vary between prostheses and patients. In the worst cases this process can lead to the late failure of the implant. To monitor such bone density evolution, we are developing a tailored Computer-aided Densitometric Image Analysis system (the major part of this our system uses an 8-bit commercial hardware with 256 levels of grey). The equivalent dynamic range of an X-ray picture is about 10 bits. In this paper we present a method to overcome these hardware limitations by improving the software. Using a double-exposure acquisition it is possible to build a 9-bit image that is good enough for most applications involving bone density measurement.
引用
收藏
页码:57 / 59
页数:3
相关论文
共 7 条
[1]   THE COMPUTER AND MEDICAL IMAGES [J].
BARBER, DC .
BRITISH MEDICAL JOURNAL, 1983, 287 (6389) :413-415
[2]  
BRAGGER U, 1988, J CLIN PERIODONTOL, V15, P27
[3]   BONE MASS DETERMINATION FROM MICRORADIOGRAPHS BY COMPUTER-ASSISTED VIDEODENSITOMETRY .2. ALUMINUM AS A REFERENCE SUBSTANCE [J].
KALEBO, P ;
STRID, KG .
ACTA RADIOLOGICA, 1988, 29 (05) :611-617
[4]   BONE-INGROWTH HIP PROSTHESES IN ASYMPTOMATIC PATIENTS - RADIOGRAPHIC FEATURES [J].
KAPLAN, PA ;
MONTESI, SA ;
JARDON, OM ;
GREGORY, PR .
RADIOLOGY, 1988, 169 (01) :221-227
[5]   A QUANTITATIVE ASSESSMENT OF CROSS-SECTIONAL CORTICAL BONE REMODELING IN THE FEMORAL DIAPHYSIS FOLLOWING HIP-ARTHROPLASTY IN ELDERLY FEMALES [J].
TORCHIA, ME ;
RUFF, CB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (06) :883-891
[6]  
WANHER HW, 1986, CRIT REV CLIN LAB SC, V24, P217
[7]   POTENTIAL ERRORS INHERENT IN QUANTITATIVE DENSITOMETRIC ANALYSIS OF ORTHOPEDIC RADIOGRAPHS - A STUDY AFTER TOTAL HIP-ARTHROPLASTY [J].
WEST, JD ;
MAYOR, MB ;
COLLIER, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (01) :58-64