Behavior of one-way reinforced concrete slabs subjected to fire

被引:22
作者
Allam, Said M. [1 ]
Elbakry, Hazem M. F. [1 ]
Rabeai, Alaa G. [1 ]
机构
[1] Alexandria Univ, Fac Engn, Struct Engn Dept, Alexandria, Egypt
关键词
Cooling; Fire resistance; Finite difference; Heat transfer; Slabs;
D O I
10.1016/j.aej.2013.09.004
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A finite difference analysis was performed to investigate the behavior of one-way reinforced concrete slabs exposed to fire. The objective of the study was to investigate the fire resistance and the fire risk after extinguishing the fire. Firstly, the fire resistance was obtained using the ISO834 standard fire without cooling phase. Secondly, the ISO834 parametric fire with cooling phase was applied to study the effect of cooling time. Accordingly, the critical time for cooling was identified and the corresponding failure time was calculated. Moreover, the maximum risk time which is the time between the fire extinguishing and the collapse of slab was obtained. Sixteen oneway reinforced concrete slabs were considered to study the effect of important parameters namely: the concrete cover thickness; the plaster; and the live load ratio. Equations for heat transfer through the slab thickness were used in the fire resistance calculations. Studying the cooling time revealed that the slabs are still prone to collapse although they were cooled before their fire resistance. Moreover, increasing the concrete cover thickness and the presence of plaster led to an increase in the maximum risk time. However, the variation in the live load ratio has almost no effect on such time. (C) 2013 Production and hosting by Elsevier B.V. on behalf of Faculty of Engineering, Alexandria University.
引用
收藏
页码:749 / 761
页数:13
相关论文
共 27 条
[1]  
ACI (American Concrete Institute), 1994, 216 ACI
[2]   Explosive spalling of normal strength concrete slabs subjected to severe fire [J].
Ali, Faris ;
Nadjai, Ali ;
Abu-Tair, Abid .
MATERIALS AND STRUCTURES, 2011, 44 (05) :943-956
[3]  
[Anonymous], 2001, RATIONAL FIRE SAFETY
[4]  
[Anonymous], 2032007 ECP MIN HOUS
[5]  
[Anonymous], EN1992122004
[6]   Behaviour of concrete floor slabs at ambient and elevated temperatures [J].
Bailey, C. G. ;
Toh, W. S. .
FIRE SAFETY JOURNAL, 2007, 42 (6-7) :425-436
[7]   Small-scale concrete slab tests at ambient and elevated temperatures [J].
Bailey, Colin G. ;
Toh, Wee Siang .
ENGINEERING STRUCTURES, 2007, 29 (10) :2775-2791
[8]   The effects of different strain contributions on the response of RC beams in fire [J].
Bratina, Sebastjan ;
Saje, Miran ;
Planinc, Igor .
ENGINEERING STRUCTURES, 2007, 29 (03) :418-430
[9]   The structural behavior and simplified thermal analysis of normal-strength and high-strength concrete beams under fire [J].
Choi, E. G. ;
Shin, Y. S. .
ENGINEERING STRUCTURES, 2011, 33 (04) :1123-1132
[10]   A numerical approach for modeling the fire induced restraint effects in reinforced concrete beams [J].
Dwaikat, M. B. ;
Kodur, V. K. R. .
FIRE SAFETY JOURNAL, 2008, 43 (04) :291-307