AMPEROMETRIC GLUCOSE SENSORS BASED ON IMMOBILIZED GLUCOSE-OXIDASE POLYQUINONE SYSTEM

被引:78
|
作者
KAKU, T
KARAN, HI
OKAMOTO, Y
机构
[1] POLYTECH INST NEW YORK,DEPT CHEM,BROOKLYN,NY 11201
[2] POLYTECH INST NEW YORK,POLYMER RES INST,BROOKLYN,NY 11201
[3] CUNY MEDGAR EVERS COLL,DEPT PHYS SCI & COMP SCI,BROOKLYN,NY 11225
关键词
D O I
10.1021/ac00080a006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-cross-linked and also cross-linked poly(ether amine quinone)s were prepared and tested for their efficiency as electron-transfer relay systems in amperometric glucose biosensors. Cyclic voltammetry and constant applied potential measurements showed that poly(ether amine quinone) relay systems efficiently mediated electron transfer from reduced glucose oxidase to a conventional carbon paste electrode. Sensors containing these relay systems respond rapidly to low (<0.1 mM) glucose concentrations and reach steady-state current responses in less than 1 min. Electrodes constructed with cross-linked polymer and glucose oxidase were stable, indicating that the glucose oxidase was trapped in the polymer matrix and did not freely diffuse away from the electrode surface into aqueous solutions. The cross-linked polymer is a large molecular system which facilitates a flow of electrons from enzyme to the electrode, acting as an electron-transfer relay system and not as a diffusional mediator.
引用
收藏
页码:1231 / 1235
页数:5
相关论文
共 50 条
  • [1] AMPEROMETRIC GLUCOSE SENSORS BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN NAFION
    RISHPON, J
    GOTTESFELD, S
    CAMPBELL, C
    DAVEY, J
    ZAWODZINSKI, TA
    ELECTROANALYSIS, 1994, 6 (01) : 17 - 21
  • [2] GLUCOSE-OXIDASE IMMOBILIZED IN POLYURETHANE MATRIX - A BIOSENSOR FOR AMPEROMETRIC ESTIMATION OF GLUCOSE
    ALVA, S
    PHADKE, RS
    GOVIL, G
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1993, 70 (4-5) : 403 - 408
  • [3] REVERSIBLY IMMOBILIZED GLUCOSE-OXIDASE IN THE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF GLUCOSE
    DEALWIS, WU
    HILL, BS
    MEIKLEJOHN, BI
    WILSON, GS
    ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2688 - 2691
  • [4] AMPEROMETRIC BIOSENSOR FOR IN-VIVO GLUCOSE SENSING BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN A REDOX HYDROGEL
    LINKE, B
    KERNER, W
    KIWIT, M
    PISHKO, M
    HELLER, A
    BIOSENSORS & BIOELECTRONICS, 1994, 9 (02): : 151 - 158
  • [5] DEVELOPMENT OF A GLUCOSE ANALYZER BASED ON IMMOBILIZED GLUCOSE-OXIDASE
    WATSON, B
    STIFEL, DN
    SEMERSKY, FE
    ANALYTICA CHIMICA ACTA, 1979, 106 (02) : 233 - 242
  • [6] OXIDATION OF GLUCOSE ON IMMOBILIZED GLUCOSE-OXIDASE
    TSUKAMOTO, T
    MORITA, S
    OKADA, J
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1982, 30 (03) : 782 - 788
  • [7] AMPEROMETRIC GLUCOSE SENSORS BASED ON FERROCENE-MODIFIED POLY(ETHYLENE OXIDE) AND GLUCOSE-OXIDASE
    HALE, PD
    LAN, HL
    BOGUSLAVSKY, LI
    KARAN, HI
    OKAMOTO, Y
    SKOTHEIM, TA
    ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) : 121 - 128
  • [8] FERROCENE MODIFIED POLYPYRROLE WITH IMMOBILIZED GLUCOSE-OXIDASE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE MICROBIOSENSORS
    DICKS, JM
    HATTORI, S
    KARUBE, I
    TURNER, APF
    YOKOZAWA, T
    ANNALES DE BIOLOGIE CLINIQUE, 1989, 47 (10) : 607 - 619
  • [9] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 47 - MICR
  • [10] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 9 (01) : 95 - 104