EVAPORATION RATE OF COPPER IN HIGH-CARBON IRON MELT UNDER REDUCED PRESSURE

被引:18
作者
CHEN, XY [1 ]
ITO, N [1 ]
NAKASHIMA, K [1 ]
MORI, K [1 ]
机构
[1] KYUSHU UNIV,FAC ENGN,FUKUOKA 812,JAPAN
来源
TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN | 1995年 / 81卷 / 10期
关键词
REACTION KINETICS; COPPER; EVAPORATION; ALLOYING ELEMENT; MASS TRANSFER; TRAMP ELEMENT; FE-C MELT; IMPURITY;
D O I
10.2355/tetsutohagane1955.81.10_959
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
For clarifying the evaporation behavior of copper from liquid iron, the evaporation rate of copper has been studied under reduced pressures of several hundred Pa in the temperature range from 1723K to 1823K. Also, the effect of alloying element on the evaporation rate were examined. The experimental results obtained are summarized as follows: (1) The first order rate equation can be applied to the change of copper content in iron with time, and then the evaporation rate of copper increased with decreasing the pressure. This fact indicates that the mass transport step in the gas phase is a rate determining step under the present experimental conditions, because the mass transfer coefficient in the gas phase is inversely proportional to pressure. (2) The apparent activation energy for removal rate of copper was calculated to be about 230 kJ/mol including the enthalpy change for the copper evaporation. (3) The evaporation rate of copper was promoted by adding sulfur, but the additions of nickel or chromium lead to the decrease of the evaporation rate of copper.
引用
收藏
页码:959 / 964
页数:6
相关论文
共 8 条
[1]  
BARIN I, 1989, THERMOCHEMICAL DATA, P490
[2]  
FISCHER AW, 1974, ARCH EISENHUTTENWES, V45, P509
[3]  
OHNO R, 1968, J IRON STEEL I, V206, P904
[4]  
Schenck H., 1959, ARCH EISENHUTTENWES, V30, P641
[5]  
Van Drunen G., 1975, IRONMAK STEELMAK, V2, P125
[6]  
WADA H, 1964, T NAT RES I METALS, V6, P96
[7]  
WARD RG, 1966, J IRON STEEL I, V204, P920
[8]  
WARD RG, 1963, J IRON STEEL I, V201, P11