USE OF OPEN-TUBULAR TRAPPING COLUMNS FOR ONLINE EXTRACTION CAPILLARY GAS-CHROMATOGRAPHY OF AQUEOUS SAMPLES

被引:0
作者
MOL, HGJ
JANSSEN, HG
CRAMERS, CA
机构
来源
HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY | 1993年 / 16卷 / 07期
关键词
ONLINE EXTRACTION GC; PHASE-SWITCHING; OPEN-TUBULAR TRAPS; STATIONARY PHASE SWELLING; LARGE VOLUME INJECTION; PTV;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The applicability of open-tubular trapping columns for on-line extraction-capillary GC analysis is evaluated. The extraction step involves sorption of the analytes from water into the stationary phase of an open-tubular column, removal of the water by purging the trap with nitrogen, and desorption of the analytes with an organic solvent. The effect of swelling of the stationary phase with organic solvents on the retention power of the trap is studied. When using pentane or hexane as swelling agent breakthrough volumes of at least 10 ml can easily be obtained for non-polar compounds. For a number of medium polarity compounds breakthrough volumes of 5 ml can be achieved when chloroform is used as the swelling agent. The required drying time is less than 1 minute. Quantitative desorption requires only 75 mul of organic solvent. Solvent elimination prior to transfer to the GC column is carried out using a PTV injector and a multidimensional GC system. The system is applied tor the analyses of river water, urine, and serum samples.
引用
收藏
页码:413 / 418
页数:6
相关论文
共 18 条
[1]   AUTOMATIC-DETERMINATION OF N-METHYLCARBAMATE PESTICIDES BY USING A LIQUID LIQUID EXTRACTOR DERIVATIZATION MODULE COUPLED ONLINE TO A GAS-CHROMATOGRAPH EQUIPPED WITH A FLAME IONIZATION DETECTOR [J].
BALLESTEROS, E ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2) :169-176
[2]   INVESTIGATION OF THE KINETIC-PROPERTIES OF PARTICLE-LOADED MEMBRANES FOR SOLID-PHASE EXTRACTION BY FORCED FLOW PLANAR CHROMATOGRAPHY [J].
FERNANDO, WPN ;
LARRIVEE, ML ;
POOLE, CF .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :588-595
[3]   SWOLLEN POLYSILOXANES AS STATIONARY PHASES IN REVERSED-PHASE OPEN-TUBULAR COLUMN LIQUID-CHROMATOGRAPHY [J].
FOLESTAD, S ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 394 (03) :455-464
[4]  
GOOSENS EC, 1990, HRC-J HIGH RES CHROM, V13, P438, DOI 10.1002/jhrc.1240130614
[5]  
GOOSENS EC, 1992, HRC-J HIGH RES CHROM, V15, P242
[6]   DETERMINATION OF ORGANOPHOSPHORUS PESTICIDES IN AQUEOUS SAMPLES BY ONLINE MEMBRANE DISK EXTRACTION AND CAPILLARY GAS-CHROMATOGRAPHY [J].
KWAKMAN, PJM ;
VREULS, JJ ;
BRINKMAN, UAT ;
GHIJSEN, RT .
CHROMATOGRAPHIA, 1992, 34 (1-2) :41-47
[7]  
Marcus Y., 1977, INTRO LIQUID STATE C
[8]   SOLID-PHASE SAMPLE PREPARATION OF NATURAL-WATERS WITH REVERSED-PHASE DISKS [J].
MCDONNELL, T ;
ROSENFELD, J ;
RAISFIROUZ, A .
JOURNAL OF CHROMATOGRAPHY, 1993, 629 (01) :41-53
[9]   MEMBRANE GAS-CHROMATOGRAPHIC SYSTEM FOR AUTOMATED EXTRACTION AND DETERMINATION OF TRACE ORGANICS IN AQUEOUS SAMPLES [J].
MELCHER, RG ;
MORABITO, PL .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2183-2188
[10]   USE OF AN OPEN-TUBULAR TRAPPING COLUMN AS PHASE-SWITCHING INTERFACE IN ONLINE COUPLED REVERSED-PHASE LIQUID-CHROMATOGRAPHY CAPILLARY GAS-CHROMATOGRAPHY [J].
MOL, HGJ ;
STANIEWSKI, J ;
JANSSEN, HG ;
CRAMERS, CA ;
GHIJSEN, RT ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2) :201-212