ULTRASOUND FOR CLOSED FEMORAL NAILING

被引:9
作者
MAHAISAVARIYA, B [1 ]
SUIBNUGARN, C [1 ]
MAIRIANG, E [1 ]
SAENGNIPANTHKUL, S [1 ]
LAUPATTARAKASEM, W [1 ]
KOSUWON, W [1 ]
机构
[1] KHON KAEN UNIV, SRINAGARIND HOSP, FAC MED, KHON KAEN, THAILAND
关键词
INTRAMEDULLARY NAILING; CLOSED; FEMORAL FRACTURE; ULTRASONOGRAPHY;
D O I
10.1002/jcu.1870190705
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A new application of operative ultrasound to help assess the fracture alignment for closed reduction and passing the guide wire in closed femoral nailing is described. This method can be used instead of fluoroscopic monitoring in certain important steps which can markedly reduce the exposure time of fluoroscopic monitoring. Nine of ten cases were successful using this technique for closed unlocked nailing with an average ultrasound monitoring time of 8 minutes. The time required for fluoroscopic assessment was reduced to less than 1 minute for each successful case.
引用
收藏
页码:393 / 397
页数:5
相关论文
共 4 条
[1]  
DAHNERS LE, 1987, CLIN ORTHOP RELAT R, P148
[2]   RADIATION EXPOSURE TO THE SURGEON DURING CLOSED INTERLOCKING INTRAMEDULLARY NAILING [J].
LEVIN, PE ;
SCHOEN, RW ;
BROWNER, BD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (05) :761-766
[3]  
Suibnugarn C, 1990, J ASEAN ORTHOP ASS, V4, P87
[4]   CLOSED INTRAMEDULLARY NAILING OF FEMORAL FRACTURES - A REPORT OF 520 CASES [J].
WINQUIST, RA ;
HANSEN, ST ;
CLAWSON, DK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (04) :529-539