A radiological method to determine the accuracy of motion capture marker placement on palpable anatomical landmarks through a shoe

被引:10
作者
Bishop, Chris [1 ]
Thewlis, Dominic [1 ,2 ]
Uden, Hayley [1 ]
Ogilvie, Denise [1 ]
Paul, Gunther [3 ]
机构
[1] Univ South Australia, Sch Hlth Sci, Adelaide, SA, Australia
[2] Univ South Australia, Sansom Inst Hlth Res, Adelaide, SA, Australia
[3] Univ South Australia, Mawson Inst, Ergo Lab, Adelaide, SA, Australia
关键词
anatomical markers; kinematic model; X-ray; reliability; foot and ankle;
D O I
10.1080/19424280.2011.635386
中图分类号
TB18 [人体工程学];
学科分类号
1201 ;
摘要
The accuracy of marker placement on palpable surface anatomical landmarks is an important consideration in biomechanics. Although marker placement reliability has been studied in some depth, it remains unclear whether or not the markers are accurately positioned over the intended landmark in order to define the static position and orientation of the segment. A novel method using commonly available X-ray imaging was developed to identify the accuracy of markers placed on the shoe surface by palpating landmarks through the shoe. An anterior-posterior and lateral-medial X-ray was taken on 24 participants with a newly developed marker set applied to both the skin and shoe. The vector magnitude of both skin-and shoe-mounted markers from the anatomical landmark was calculated, as well as the mean marker offset between skin-and shoe-mounted markers. The accuracy of placing markers on the shoe relative to the skin-mounted markers, accounting for shoe thickness, was less than 5 mm for all markers studied. Further, when using the developed guidelines provided in this study, the method was deemed reliable (Intra-rater ICCs = 0.50-0.92). In conclusion, the method proposed here can reliably assess marker placement accuracy on the shoe surface relative to chosen anatomical landmarks beneath the skin.
引用
收藏
页码:169 / 177
页数:9
相关论文
共 11 条
[1]   POSITION AND ORIENTATION IN-SPACE OF BONES DURING MOVEMENT - ANATOMICAL FRAME DEFINITION AND DETERMINATION [J].
CAPPOZZO, A ;
CATANI, F ;
DELLA CROCE, U ;
LEARDINI, A .
CLINICAL BIOMECHANICS, 1995, 10 (04) :171-178
[2]   Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis [J].
Carson, MC ;
Harrington, ME ;
Thompson, N ;
O'Connor, JJ ;
Theologis, TN .
JOURNAL OF BIOMECHANICS, 2001, 34 (10) :1299-1307
[3]  
Collins P.J., 2010, RAD DOSIMETRY REPORT
[4]  
Field D., 2001, ANATOMY PALPATION SU
[5]   Assessment of the kinematic variability among 12 motion analysis laboratories [J].
Gorton, George E., III ;
Hebert, David A. ;
Gannotti, Mary E. .
GAIT & POSTURE, 2009, 29 (03) :398-402
[6]   REPEATABILITY OF KINEMATIC, KINETIC, AND ELECTROMYOGRAPHIC DATA IN NORMAL ADULT GAIT [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME ;
GAINEY, J ;
GORTON, G ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :849-860
[7]  
Kadambande S, 2006, FOOT, V16, P188, DOI [DOI 10.1016/J.FOOT.2006.06.001, DOI 10.1016/J.F00T.2006.06.001]
[8]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[9]   Rear-foot, mid-foot and fore-foot motion during the stance phase of gait [J].
Leardini, A. ;
Benedetti, M. G. ;
Berti, L. ;
Bettinelli, D. ;
Nativo, R. ;
Giannini, S. .
GAIT & POSTURE, 2007, 25 (03) :453-462
[10]   Effect of foot orthoses on the kinematics and kinetics of normal walking gait [J].
Nester, CJ ;
van der Linden, ML ;
Bowker, P .
GAIT & POSTURE, 2003, 17 (02) :180-187