An uncertainty metric to evaluate deformation vector fields for dose accumulation in radiotherapy

被引:5
作者
Takemura, Akihiro [1 ]
Nagano, Akira [2 ]
Kojima, Hironori [3 ,5 ]
Ikeda, Tomohiro [4 ]
Yokoyama, Noriomi [5 ]
Tsukamoto, Kosuke [3 ]
Noto, Kimiya [3 ]
Isomura, Naoki [3 ]
Ueda, Shinichi [3 ]
Kawashima, Hiroki [1 ]
机构
[1] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Okayama Univ Hosp, Div Radiol, Kita Ku, 2-5-1 Shikatacho, Okayama 7008558, Japan
[3] Kanazawa Univ Hosp, Dept Radiol Technol, 13-1 Takaramachi, Kanazawa, Ishikawa 9208641, Japan
[4] Southern Tohoku Proton Therapy Ctr, Dept Radiat Oncol, 7-115 Yatsuyamada, Koriyama, Fukushima 9638563, Japan
[5] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
基金
日本学术振兴会;
关键词
Deformable image registration; Uncertainty; Deformation vector field correctness; Radiotherapy;
D O I
10.1016/j.phro.2018.05.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: In adaptive radiotherapy, deformable image registration (DIR) is used to propagate delineations of tumors and organs into a new therapy plan and to calculate the accumulated total dose. Many DIR accuracy metrics have been proposed. An alternative proposed here could be a local uncertainty (LU) metric for DIR results. Materials and methods: The LU represented the uncertainty of each DIR position and was focused on deformation evaluation in uniformly-dense regions. Four cases demonstrated LU calculations: two head and neck cancer cases, a lung cancer case, and a prostate cancer case. Each underwent two CT examinations for radiotherapy planning. Results: LU maps were calculated from each DIR of the clinical cases. Reduced fat regions had LUs of 4.6 +/- 0.9 mm, 4.8 +/- 1.0 mm, and 4.5 +/- 0.7 mm, while the shrunken left parotid gland had a LU of 4.1 +/- 0.8mm and the shrunken lung tumor had a LU of 3.7 +/- 0.7 mm. The bowels in the pelvic region had a LU of 10.2 +/- 3.7 mm. LU histograms for the cases were similar and 99% of the voxels had a LU < 3 mm. Conclusions: LU is a new uncertainty metric for DIR that was demonstrated for clinical cases. It had a tolerance of < 3 mm.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 50 条
[21]   A practical EPR dosimetry system for routine use in radiotherapy: uncertainty analysis of lithium formate dosimeters at the therapeutic dose level [J].
Hoefel, Sebastian ;
Stehle, Michael ;
Zwicker, Felix ;
Fix, Michael K. ;
Drescher, Malte .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (04)
[22]   Should dose from small fields be limited for dose verification procedures?: uncertainty versus small field dose in VMAT treatments [J].
Wolfs, Cecile J. A. ;
Swinnen, Ans C. C. ;
Nijsten, Sebastiaan M. J. J. G. ;
Verhaegen, Frank .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (20)
[23]   Deformable Image Registration Uncertainty-Encompassing Dose Accumulation for Adaptive Radiation Therapy [J].
Meyer, Sebastian ;
Hu, Yu-Chi ;
Rimner, Andreas ;
Mechalakos, James ;
Cervin, Laura ;
Zhang, Pengpeng .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2025, 122 (04) :818-826
[24]   Integration of operator-validated contours in deformable image registration for dose accumulation in radiotherapy [J].
Bosma, Lando S. ;
Ries, Mario ;
de Senneville, Baudouin Denis ;
Raaymakers, Bas W. ;
Zachiu, Cornel .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
[25]   CBCT-based deformable dose accumulation of external beam radiotherapy in cervical cancer [J].
Fischer, Andrea M. M. ;
Hague, Thomas ;
Hoskin, Peter J. J. .
ACTA ONCOLOGICA, 2023, 62 (08) :923-931
[26]   Adaptive radiotherapy for NSCLC patients: utilizing the principle of energy conservation to evaluate dose mapping operations [J].
Zhong, Hualiang ;
Chetty, Indrin J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11) :4333-4345
[27]   Incorporating Uncertainty Into Multiscale Parameter Regionalization to Evaluate the Performance of Nationally Consistent Parameter Fields for a Hydrological Model [J].
Lane, Rosanna A. ;
Freer, Jim E. ;
Coxon, Gemma ;
Wagener, Thorsten .
WATER RESOURCES RESEARCH, 2021, 57 (10)
[28]   Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy [J].
Kim, Hojin ;
Chen, Josephine ;
Phillips, Justin ;
Pukala, Jason ;
Yom, Sue S. ;
Kirby, Neil .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) :885-892
[29]   Head and neck IMPT probabilistic dose accumulation: Feasibility of a 2 mm setup uncertainty setting [J].
Wagenaar, Dirk ;
Kierkels, Roel G. J. ;
van der Schaaf, Arjen ;
Meijers, Arturs ;
Scandurra, Daniel ;
Sijtsema, Nanna M. ;
Korevaar, Erik W. ;
Steenbakkers, Roel J. H. M. ;
Knopf, Antje C. ;
Langendijk, Johannes A. ;
Both, Stefan .
RADIOTHERAPY AND ONCOLOGY, 2021, 154 :45-52
[30]   Dose accumulation to assess the validity of treatment plans with reduced margins in radiotherapy of head and neck cancer [J].
Lowther, Nicholas J. ;
Marsh, Steven H. ;
Louwe, Robert J. W. .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 14 :53-60