An uncertainty metric to evaluate deformation vector fields for dose accumulation in radiotherapy

被引:5
作者
Takemura, Akihiro [1 ]
Nagano, Akira [2 ]
Kojima, Hironori [3 ,5 ]
Ikeda, Tomohiro [4 ]
Yokoyama, Noriomi [5 ]
Tsukamoto, Kosuke [3 ]
Noto, Kimiya [3 ]
Isomura, Naoki [3 ]
Ueda, Shinichi [3 ]
Kawashima, Hiroki [1 ]
机构
[1] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Okayama Univ Hosp, Div Radiol, Kita Ku, 2-5-1 Shikatacho, Okayama 7008558, Japan
[3] Kanazawa Univ Hosp, Dept Radiol Technol, 13-1 Takaramachi, Kanazawa, Ishikawa 9208641, Japan
[4] Southern Tohoku Proton Therapy Ctr, Dept Radiat Oncol, 7-115 Yatsuyamada, Koriyama, Fukushima 9638563, Japan
[5] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2018年 / 6卷
基金
日本学术振兴会;
关键词
Deformable image registration; Uncertainty; Deformation vector field correctness; Radiotherapy;
D O I
10.1016/j.phro.2018.05.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: In adaptive radiotherapy, deformable image registration (DIR) is used to propagate delineations of tumors and organs into a new therapy plan and to calculate the accumulated total dose. Many DIR accuracy metrics have been proposed. An alternative proposed here could be a local uncertainty (LU) metric for DIR results. Materials and methods: The LU represented the uncertainty of each DIR position and was focused on deformation evaluation in uniformly-dense regions. Four cases demonstrated LU calculations: two head and neck cancer cases, a lung cancer case, and a prostate cancer case. Each underwent two CT examinations for radiotherapy planning. Results: LU maps were calculated from each DIR of the clinical cases. Reduced fat regions had LUs of 4.6 +/- 0.9 mm, 4.8 +/- 1.0 mm, and 4.5 +/- 0.7 mm, while the shrunken left parotid gland had a LU of 4.1 +/- 0.8mm and the shrunken lung tumor had a LU of 3.7 +/- 0.7 mm. The bowels in the pelvic region had a LU of 10.2 +/- 3.7 mm. LU histograms for the cases were similar and 99% of the voxels had a LU < 3 mm. Conclusions: LU is a new uncertainty metric for DIR that was demonstrated for clinical cases. It had a tolerance of < 3 mm.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 50 条
  • [21] CBCT-based deformable dose accumulation of external beam radiotherapy in cervical cancer
    Fischer, Andrea M. M.
    Hague, Thomas
    Hoskin, Peter J. J.
    ACTA ONCOLOGICA, 2023, 62 (08) : 923 - 931
  • [22] Adaptive radiotherapy for NSCLC patients: utilizing the principle of energy conservation to evaluate dose mapping operations
    Zhong, Hualiang
    Chetty, Indrin J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11) : 4333 - 4345
  • [23] Integration of operator-validated contours in deformable image registration for dose accumulation in radiotherapy
    Bosma, Lando S.
    Ries, Mario
    de Senneville, Baudouin Denis
    Raaymakers, Bas W.
    Zachiu, Cornel
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [24] Incorporating Uncertainty Into Multiscale Parameter Regionalization to Evaluate the Performance of Nationally Consistent Parameter Fields for a Hydrological Model
    Lane, Rosanna A.
    Freer, Jim E.
    Coxon, Gemma
    Wagener, Thorsten
    WATER RESOURCES RESEARCH, 2021, 57 (10)
  • [25] Dose accumulation to assess the validity of treatment plans with reduced margins in radiotherapy of head and neck cancer
    Lowther, Nicholas J.
    Marsh, Steven H.
    Louwe, Robert J. W.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 14 : 53 - 60
  • [26] Head and neck IMPT probabilistic dose accumulation: Feasibility of a 2 mm setup uncertainty setting
    Wagenaar, Dirk
    Kierkels, Roel G. J.
    van der Schaaf, Arjen
    Meijers, Arturs
    Scandurra, Daniel
    Sijtsema, Nanna M.
    Korevaar, Erik W.
    Steenbakkers, Roel J. H. M.
    Knopf, Antje C.
    Langendijk, Johannes A.
    Both, Stefan
    RADIOTHERAPY AND ONCOLOGY, 2021, 154 : 45 - 52
  • [27] Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy
    Kim, Hojin
    Chen, Josephine
    Phillips, Justin
    Pukala, Jason
    Yom, Sue S.
    Kirby, Neil
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 885 - 892
  • [28] The effect on dose accumulation accuracy of inverse-consistency and transitivity error reduced deformation maps
    Nicholas Hardcastle
    Edward T. Bender
    Wolfgang A. Tomé
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 321 - 326
  • [29] Evaluation of dose calculation accuracy of a commercial radiotherapy treatment planning system for adjacent radiation fields
    Rasouli, Ali
    Arani, Mahmud Naraqi
    Aliasgharzadeh, Akbar
    Farhood, Bagher
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22
  • [30] The effect on dose accumulation accuracy of inverse-consistency and transitivity error reduced deformation maps
    Hardcastle, Nicholas
    Bender, Edward T.
    Tome, Wolfgang A.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (02) : 321 - 326